INSPECTION
Inspection · Vehicles built from Oct 2006
| INSPECT HEADLIGHT CLEANER CONTROL RELAY (w/ Headlight Cleaner System) |
Inspect headlight cleaner control relay operation.

Measure the resistance between terminals A39-4 (E) and A39-6 (PB).
Connect the positive (+) battery lead to terminal A39-3 (IG) of the connector, and the negative (-) battery lead to terminal A39-4 (E).
Connect the negative (-) battery lead to terminals A39-1 (HDLO) and A39-2 (H), and measure the resistance between terminals A39-4 (E) and A39-6 (PB).
- Standard resistance:
Tester Connection
Condition
Specified Condition
A39-4 (E) - A39-6 (PB)
Always
10 kΩ or higher
A39-4 (E) - A39-6 (PB)
When applying battery voltage
Below 1 Ω
A39-4 (E) - A39-6 (PB)
0.8 to 0.9 seconds after applying battery voltage
10 kΩ or higher
Disconnect the negative (-) battery lead from terminal A39-1 (HDLO) and A39-2 (H).
Disconnect the positive (+) battery lead from terminal A39-3 (IG), and then reconnect it.
Connect the negative (-) battery lead to terminals A39-1 (HDLO) and A39-5 (FRWA), and measure the resistance between terminals A39-4 (E) and A39-6 (PB).

- Standard resistance:
Tester Connection
Condition
Specified Condition
A39-4 (E) - A39-6 (PB)
When applying battery voltage
Below 1 Ω
A39-4 (E) - A39-6 (PB)
0.8 to 0.9 seconds after applying battery voltage
10 kΩ or higher