DTC P0037 Oxygen Sensor Heater Control Circuit Low (Bank 1 Sensor 2) |
DTC P0038 Oxygen Sensor Heater Control Circuit High (Bank 1 Sensor 2) |


| DTC No. | DTC Detection Condition | Trouble Area |
| P0037 | Heated oxygen sensor heater (sensor 2) current is less than 0.3 A (1 trip detection logic) |
|
| P0038 | Heated oxygen sensor heater (sensor 2) current is fail (1 trip detection logic) |
|
| 1.INSPECT HEATED OXYGEN SENSOR (HEATER RESISTANCE) |
![]() |
Disconnect the heated oxygen sensor connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 (HT1B) - 2 (+B) | 20°C (68°F) | 11 to 16 Ω |
| 1 (HT1B) - 4 (E2) | Always | 10 kΩ or higher |
| *1 | Component without harness connected (Heated Oxygen Sensor) |
Reconnect the heated oxygen sensor connector.
|
| ||||
| OK | |
| 2.CHECK TERMINAL VOLTAGE (+B OF HEATED OXYGEN SENSOR) |
![]() |
Disconnect the heated oxygen sensor connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| C22-2 (+B) - Body ground | Ignition switch ON | 11 to 14 V |
| *1 | Front view of wire harness connector (to Heated Oxygen Sensor) |
Reconnect the heated oxygen sensor connector.
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (HEATED OXYGEN SENSOR - ECM) |
Disconnect the heated oxygen sensor connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| C22-1 (HT1B) - C24-47 (HT1B) | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
| C22-1 (HT1B) or C24-47 (HT1B) - Body ground | Always | 10 kΩ or higher |
Reconnect the heated oxygen sensor connector.
Reconnect the ECM connector.
|
| ||||
| OK | ||
| ||