AIR CONDITIONING SYSTEM > DATA LIST / ACTIVE TEST |
| DATA LIST |
Connect the intelligent tester to the DLC3.
Turn the ignition switch to the ON position.
Turn the tester on.
Enter the following menus: Body / Air Conditioner / Data List.
Check the value(s) by referring to the table below.
| Item | Measurement Item / Display (Range) | Normal Condition | Diagnostic Note |
| Room Temperature Sensor (Room Temp) | Room temperature sensor / Min.: -6.5°C (20.3°F), Max.: 57.25°C (135.05°F) | Actual cabin temperature is displayed | - |
| Ambient Temp Sensor (Ambi Temp Sens) | Ambient temperature sensor / Min.: -23.3°C (-9.94°F), Max.: 65.95°C (150.71°F) | Actual ambient temperature is displayed | - |
| Adjusted Ambient Temp (Ambi Temp) | Adjusted ambient temperature / Min.: -30.8°C (-23.44°F), Max.: 50.8°C (123.44°F) | - | - |
| Evaporator Fin Thermistor (Evap Fin Temp) | Evaporator fin thermistor / Min.: -29.7°C (-21.46°F), Max.: 59.55°C (139.19°F) | Actual evaporator temperature is displayed | - |
| Solar Sensor (D side) (Solar Sens-D) | Driver side solar sensor / Min.: 0, Max.: 255 | Driver side solar sensor value increases as brightness increases | - |
| Solar Sensor (P side) (Solar Sens-P) | Passenger side solar sensor / Min.: 0, Max.: 255 | Passenger side solar sensor value increases as brightness increases | - |
| Engine Coolant Temp (Coolant Temp) | Engine coolant temperature / Min.: 1.3°C (34.34°F), Max.: 90.55°C (194.99°F) | Actual engine coolant temperature is displayed while engine is warmed up | - |
| Set Temperature (D side) (Set Temp-D) | Driver side set temperature / Min.: 0°C (32°F), Max.: 30°C (54°F) | Driver side set temperature is displayed | - |
| Set Temperature (P side) (Set Temp-P) | Passenger side set temperature / Min.: 0°C (32°F), Max.: 30°C (54°F) | Passenger side set temperature is displayed | - |
| Estimated Temp-D (Estimate Temp-D) | Driver side estimate temperature / Min.: -358.4°C (-613.12°F), Max.: 358.4°C (677.12°F) | Damper is at "MAX. COOL": -358.4°C (-613.12°F) Damper is at "MAX. HOT": 358.4°C (677.12°F) | - |
| Estimated Temp-P (Estimate Temp-P) | Passenger side estimate temperature / Min.: -358.4, Max.: 358.4 | Damper is at "MAX. COOL": -358.4°C (-613.12°F) Damper is at "MAX. HOT": 358.4°C (677.12°F) | - |
| Blower Motor Speed Level (Blower Level) | Blower motor speed level / Min.: 0 level, Max.: 31 level | Increases in the range between 0 and 31 as the blower motor speed increases | - |
| Regulator Pressure Sensor (Reg Press Sens) | Regulator pressure sensor / Min.: -0.5 kgf/cm2G, Max.: 37.75 kgf/cm2G | Actual refrigerant pressure is displayed | - |
| Regulator Control Current (Reg Ctrl Currnt) | Compressor variable output current / Min.: 0 A, Max.: 0.996 A | - | - |
| Air Mix Servo Target Pulse(D) (Air Mix Pulse-D) | Driver side air mix servo motor target pulse / Min.: 0, Max.: 255 | LHD:
RHD:
| - |
| Air Mix Servo Targ Pulse(P) (Air Mix Pulse-P) | Passenger side air mix servo motor target pulse / Min.: 0, Max.: 255 | LHD:
RHD:
| - |
| Air Outlet Servo Pulse (D) (Air Out Pulse-D) | Driver side air outlet servo motor target pulse / Min.: 0, Max.: 255 | FACE: 8 (pulse) B/L: 30 to 38 (pulse) FOOT: 50 to 74 (pulse) FOOT/DEF: 80 (pulse) DEF: 97 (pulse) | - |
| Air Inlet Damper Target Pulse (A/I Damp Targ Pls) | Air inlet damper target pulse / Min.: 0, Max.: 255 | RECIRCULATION: 7 (pulse) FRESH: 28 (pulse) | - |
| Number of Trouble Codes (#Codes) | Number of trouble codes / Min.: 0, Max.: 255 | Number of DTCs will be displayed | - |
| Item | Measurement Item / (Range) Display | Normal Condition | Diagnostic Note |
| A/C Signal (A/C Signal) | A/C signal / ON or OFF | ON: A/C ON OFF: A/C OFF | - |
| A/C Magnetic Clutch Relay (A/C Mag Clutch) | A/C magnetic clutch relay / ON or OFF | ON: A/C magnetic clutch ON OFF: A/C magnetic clutch OFF | - |
| ACTIVE TEST |
Connect the intelligent tester to the DLC3.
Turn the ignition switch to the ON position.
Turn the tester on.
Enter the following menus: Body / Air Conditioner / Active Test.
Perform the Active Test by referring to the table below.
| Item | Test Details / Display (Range) | Diagnostic Note |
| Blower Motor (Blower Motor) | Blower motor / Min.: Level 0, Max.: Level 31 | - |
| Defogger Relay (Rear) (Defogger Rly-R) | Defogger relay (Rear) / OFF, ON | - |
| Air Mix Servo Targ Pulse(D) (Air Mix Pulse-D) | Driver side air mix servo motor pulse / Min.: 0, Max.: 255 | - |
| Air Mix Servo Targ Pulse(P) (Air Mix Pulse-P) | Passenger side air mix servo motor pulse / Min.: 0, Max.: 255 | - |
| Air Outlet Servo Pulse (D) (Air Out Pulse-D) | Driver side air outlet servo motor pulse / Min.: 0, Max.: 255 | - |
| Air Inlet Damper Targ Pulse (A/I Damp Targ Pls) | Air inlet damper target pulse / Min.: 0, Max.: 255 | - |
| Item | Test Details / Display (Range) | Diagnostic Note |
| A/C Magnet Clutch (Control the A/C Magnet Clutch) | Magnetic clutch relay / ON or OFF | - |