DTC B1412/12 Ambient Temperature Sensor Circuit |
| DTC No. | DTC Detection Condition | Trouble Area |
| B1412/12 | Open or short in ambient temperature sensor circuit |
|

| 1.READ VALUE USING INTELLIGENT TESTER |
Connect the intelligent tester to the DLC3.
Turn the ignition switch to the ON position and turn the intelligent tester main switch on.
Select the item below in the Data List, and read the display on the intelligent tester.
| Item | Measurement Item / Display (Range) | Normal Condition | Diagnostic Note |
| Ambient Temp Sensor (Ambi Temp Sens) | Ambient temperature sensor / Min: -23.3°C (-9.94°F), Max: 65.95°C (150.71°F) | Actual ambient temperature is displayed | Open in circuit: -23.3°C (-9.94°F) Short in circuit: 65.95°C (150.71°F) |
| Result | Proceed to |
| NG | A |
| OK (When troubleshooting according to the PROBLEM SYMPTOMS TABLE) | B |
| OK (When troubleshooting according to the DTC) | C |
|
| ||||
|
| ||||
| A | |
| 2.INSPECT AIR CONDITIONING AMPLIFIER |
![]() |
Remove the A/C amplifier with the connectors still connected.
Turn the ignition switch to the ON position.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| E38-5 (TAM) - E38-13 (SG-2) | Ignition switch: ON at 25°C (77°F) | 1.35 to 1.75 V |
| E38-5 (TAM) - E38-13 (SG-2) | Ignition switch: ON at 40°C (104°F) | 0.9 to 1.2 V |
| Result | Proceed to |
| NG | A |
| OK (When troubleshooting according to the PROBLEM SYMPTOMS TABLE) | B |
| OK (When troubleshooting according to the DTC) | C |
|
| ||||
|
| ||||
| A | |
| 3.INSPECT AMBIENT TEMPERATURE SENSOR |
![]() |
Remove the ambient temperature sensor.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A2-1 - A2-2 | 10°C (50°F) | 3.00 to 3.73 kΩ |
| A2-1 - A2-2 | 15°C (59°F) | 2.45 to 2.88 kΩ |
| A2-1 - A2-2 | 20°C (68°F) | 1.95 to 2.30 kΩ |
| A2-1 - A2-2 | 25°C (77°F) | 1.60 to 1.80 kΩ |
| A2-1 - A2-2 | 30°C (86°F) | 1.28 to 1.47 kΩ |
| A2-1 - A2-2 | 35°C (95°F) | 1.00 to 1.22 kΩ |
| A2-1 - A2-2 | 40°C (104°F) | 0.80 to 1.00 kΩ |
| A2-1 - A2-2 | 45°C (113°F) | 0.65 to 0.85 kΩ |
| A2-1 - A2-2 | 50°C (122°F) | 0.50 to 0.70 kΩ |
| A2-1 - A2-2 | 55°C (131°F) | 0.44 to 0.60 kΩ |
| A2-1 - A2-2 | 60°C (140°F) | 0.36 to 0.50 kΩ |
|
| ||||
| OK | |
| 4.CHECK HARNESS AND CONNECTOR (AMBIENT TEMPERATURE SENSOR - A/C AMPLIFIER) |
![]() |
Disconnect the ambient temperature sensor connector.
![]() |
Disconnect the A/C amplifier connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A2-2 - E38-5 (TAM) | Always | Below 1 Ω |
| A2-1 - E38-13 (SG-2) | Always | Below 1 Ω |
| E38-5 (TAM) - Body ground | Always | 10 kΩ or higher |
| E38-13 (SG-2) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||