Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › AIR CONDITIONING SYSTEM

DTC    B1413/13    Evaporator Temperature Sensor Circuit

for Preparation Click here


DESCRIPTION

The evaporator temperature sensor (A/C thermistor) is installed on the evaporator in the air conditioning unit. It detects the temperature of the cooled air that has passed through the evaporator and its signal is used to control the air conditioning. It sends a signal to the A/C amplifier. The resistance of the evaporator temperature sensor (A/C thermistor) changes in accordance with the temperature of the cooled air that has passed through the evaporator. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The A/C amplifier applies voltage (5 V) to the evaporator temperature sensor (A/C thermistor) and reads voltage changes as the resistance of the evaporator temperature sensor (A/C thermistor) changes. This sensor is used to prevent the evaporator from freezing.

DTC No.
DTC Detection Condition
Trouble Area
B1413/13
Open or short in evaporator temperature sensor circuit
  1. Air conditioning harness (evaporator temperature sensor)
  2. A/C amplifier

WIRING DIAGRAM


E118397E03


INSPECTION PROCEDURE

1.READ VALUE USING INTELLIGENT TESTER
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch to the ON position and turn the intelligent tester main switch on.

  1. Select the item below in the Data List, and read the display on the intelligent tester.

    Data List / Air Conditioner: 
    Item
    Measurement Item / Display
    (Range)
    Normal Condition
    Diagnostic Note
    Evaporator Fin Thermistor
    (Evap Fin Temp)
    Evaporator fin thermistor / Min.: -29.7°C (-21.46°F), Max.: 59.55°C (139.19°F)
    Actual evaporator temperature is displayed
    Open in circuit: -29.7°C (-21.46°F)
    Short in circuit: 59.55°C (139.19°F)

    OK:
    The display is as specified in the normal condition column.


    Result:

    Result
    Proceed to
    NG
    A
    OK (When troubleshooting according to the PROBLEM SYMPTOMS TABLE)
    B
    OK (When troubleshooting according to the DTC)
    C



B
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE

C
REPLACE AIR CONDITIONING AMPLIFIER
A


2.INSPECT AIR CONDITIONING HARNESS


    E124474E01
  1. Remove the air conditioning harness (evaporator temperature sensor).

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    e1-5 - e1-6
    -10°C (14°F)
    7.30 to 9.10 kΩ
    e1-5 - e1-6
    -5°C (23°F)
    5.65 to 6.95 kΩ
    e1-5 - e1-6
    0°C (32°F)
    4.40 to 5.35 kΩ
    e1-5 - e1-6
    5°C (41°F)
    3.40 to 4.15 kΩ
    e1-5 - e1-6
    10°C (50°F)
    2.70 to 3.25 kΩ
    e1-5 - e1-6
    15°C (59°F)
    2.14 to 2.58 kΩ
    e1-5 - e1-6
    20°C (68°F)
    1.71 to 2.05 kΩ
    e1-5 - e1-6
    25°C (77°F)
    1.38 to 1.64 kΩ
    e1-5 - e1-6
    30°C (86°F)
    1.11 to 1.32 kΩ

    NOTICE:
    1. Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
    2. When measuring, the sensor temperature must be the same as the ambient temperature.

    HINT:
    As the temperature increases, the resistance decreases (see the graph).



NG
REPLACE AIR CONDITIONING HARNESS
OK

REPLACE AIR CONDITIONING AMPLIFIER