SLIDING ROOF SYSTEM > Sliding Roof ECU Power Source Circuit |

| 1.PERFORM ACTIVE TEST USING INTELLIGENT TESTER (SLIDING ROOF OPERATION) |
Select the ACTIVE TEST, use the intelligent tester to generate a control command, and then check that the sliding roof slides open/close and tilts up/down.
| Tester Display | Test Part | Control Range | Diagnostic Note |
| Slide Roof (Slide Roof) | Operate sliding roof SLIDE CLOSE/TILT UP | CLOS/UP: Sliding roof SLIDE CLOSE or TILT UP operation occurs. OFF: Sliding roof is not operating | - |
| Slide Roof (Slide Roof) | Operate sliding roof SLIDE OPEN/TILT DOWN | OPN/DWN: Sliding roof SLIDE OPEN or TILT DOWN operation occurs OFF: Sliding roof is not operating | - |
|
| ||||
| OK | ||
| ||
| 2.INSPECT FUSE (S/ROOF, ECU-IG NO. 1) |
Remove the S/ROOF and ECU-IG No. 1 fuses from the instrument panel J/B.
Measure the resistance of the fuses.
|
| ||||
| OK | |
| 3.CHECK WIRE HARNESS (SLIDING ROOF CONTROL ECU - BATTERY AND BODY GROUND) |
![]() |
Disconnect the Q12 connector.
Measure the voltage and resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| B (Q12-1) - Body ground | Always | 10 to 14 V |
| IG (Q12-5) - Body ground | Ignition switch on (IG) | 10 to 14 V |
| IG (Q12-5) - Body ground | Ignition switch off | Below 1 V |
| Tester Connection | Specified Condition |
| E (Q12-2) - Body ground | Below 1 Ω |
|
| ||||
| OK | ||
| ||