CAN COMMUNICATION SYSTEM (for RHD) > Yaw Rate Sensor Communication Stop Mode |
| Detection Item | Symptom | Trouble Area |
| Yaw Rate Sensor Communication Stop Mode |
|
|

| 1.CHECK OPEN IN CAN BUS WIRE (YAW RATE SENSOR BRANCH WIRE) |
Turn the ignition switch off.
Disconnect the yaw rate sensor connector.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Value |
| E34-3 (CANH) - E34-2 (CANL) | Ignition switch off | 54 to 69 Ω |
|
| ||||
| OK | |
| 2.CHECK WIRE HARNESS (IG, GND) |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Value |
| E34-1 (GND) - Body ground | Always | Below 1 Ω |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Value |
| E34-5 (IG) - Body ground | Ignition switch on | 10 to 14 V |
|
| ||||
| OK | ||
| ||