AUTOMATIC TRANSAXLE SYSTEM > Transmission Control Switch Circuit |

| 1.CHECK HARNESS AND CONNECTOR (BATTERY - TRANSMISSION CONTROL SWITCH) |
![]() |
Disconnect the transmission control switch connector of the shift lock control unit assembly.
Measure the voltage according to the value(s) in the table below.
| Switch Condition | Tester Connection | Specified Condition |
| Ignition switch ON | 3 - Body ground | 10 to 14 V |
| Ignition switch OFF | Below 1 V |
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (TRANSMISSION CONTROL SWITCH - BODY GROUND) |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition |
| 5 - Body ground | Below 1 Ω |
|
| ||||
| OK | |
| 3.INSPECT TRANSMISSION CONTROL SWITCH |
![]() |
Measure the resistance between each terminal of the shift lock control unit assembly when the shift lever is moved to each position.
| Shift Position | Tester Connection | Specified Condition |
| S, "+" and "-" | 3 - 7 | Below 1 Ω |
| Except S, "+" and "-" | 10 kΩ or higher | |
| Press continuously "+" (Up shift) | 2 - 5 | Below 1 Ω |
| S | 10 kΩ or higher | |
| Press continuously "-" (Down shift) | 1 - 5 | Below 1 Ω |
| S | 10 kΩ or higher |
|
| ||||
| OK | |
| 4.CHECK HARNESS AND CONNECTOR (TRANSMISSION CONTROL SWITCH - ECM) |
![]() |
Connect the transmission control switch connector of the shift lock control unit assembly.
Disconnect the A24*1 or A55*2 ECM connector.
Turn the ignition switch on, and measure the voltage according to the value(s) in the table below when the shift lever is moved to each position.
| Shift Position | Tester Connection | Specified Condition |
| S, "+" and "-" | A24-25*1 (S) - Body ground A55-25*2 (S) - Body ground | 10 to 14 V |
| Except S, "+" and "-" | Below 1 V |
Turn the ignition switch off.
Disconnect the ECM connector.
*1: for RHD
*2: for LHD
Measure the resistance according to the value(s) in the table below when the shift lever is moved to each position.
| Shift Position | Tester Connection | Specified Condition |
| Press continuously "+" (Up shift) | A24-16*1 (SFTU) - Body ground A55-16*2 (SFTU) - Body ground | Below 1 Ω |
| S | 10 kΩ or higher | |
| Press continuously "-" (Down shift) | A24-51*1 (SFTD) - Body ground A55-51*2 (SFTD) - Body ground | Below 1 Ω |
| S | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||