POWER WINDOW MASTER SWITCH > INSPECTION |
| 1. INSPECT POWER WINDOW MASTER SWITCH |
![]() |
Measure the resistance when the switch is operated according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| 8 (UP) - 1 (E) - 4 (AUTO) | Auto UP | Below 1 Ω |
| 5 (DN) - 6 (B) | Below 1 Ω | |
| 8 (UP) - 1 (E) | Manual UP | Below 1 Ω |
| 5 (DN) - 6 (B) | Below 1 Ω | |
| 8 (UP) - 5 (DN) - 6 (B) | OFF | Below 1 Ω |
| 5 (DN) - 1 (E) | Manual DOWN | Below 1 Ω |
| 8 (UP) - 6 (B) | Below 1 Ω | |
| 4 (AUTO) - 5 (DN) - 1 (E) | Auto DOWN | Below 1 Ω |
| 8 (UP) - 6 (B) | Below 1 Ω | |
| 1 (E) - 10 (RRU) | Lock/Unlock switch | UNLOCK (Below 1 Ω) → LOCK (10 kΩ or higher) |
| 1 (E) - 12 (RLU) | ||
| 1 (E) - 13 (RLD) | ||
| 1 (E) - 15 (PD) | ||
| 1 (E) - 16 (PU) | ||
| 1 (E) - 18 (RRD) |