VEHICLE STABILITY CONTROL SYSTEM > TERMINALS OF ECU |
| Terminal of ECU |

| Symbols (Terminal No.) | Terminal Description |
| GND2 (1) | Pump motor ground |
| BM (2) | Motor relay input |
| FR+ (3) | Front wheel speed RH signal (+) input |
| FL- (4) | Front wheel speed LH signal (-) input |
| RR+ (5) | Rear wheel speed RH signal (+) input |
| RL- (6) | Rear wheel speed LH signal (-) input |
| CANH (11) | CAN communication line H |
| SP1 (12) | Speed signal output for combination meter |
| D/G (13) | Diagnosis tester communication line |
| MRF (14) | Fail safe motor relay output |
| MR (15) | Motor relay output |
| FR- (17) | Front wheel speed RH signal (-) input |
| FL+ (18) | Front wheel speed LH signal (+) input |
| RR- (19) | Rear wheel speed RH signal (-) input |
| RL+ (20) | Rear wheel speed LH signal (+) input |
| TS (24) | Test mode (signal check) input |
| CANL (25) | CAN communication line L |
| STP (27) | Stop light switch input |
| BZ (30) | Skid control buzzer output |
| +BS (31) | Solenoid relay power supply |
| GND1 (32) | Skid control ECU ground |
| WFSE (42) | WFSE input |
| R+ (45) | Power supply for motor relay |
| IG1 (46) | IG1 power supply |
| Terminal Inspection |
Disconnect the connector and measure the voltage or resistance on the wire harness side.

| Symbols (Terminal No.) | Wiring Color | Terminal Description | Condition | Specified Condition |
| GND2 (A26-1) - Body ground | W-B - Body ground | Pump motor ground | Ignition switch off | Below 1 Ω |
| STP (A26-27) - Body ground | P - Body ground | Stop light switch input | Stop light switch ON → OFF (Brake pedal depressed → released) | 8 to 14 V → Below 1.5 V |
| BZ (A26-30) - Body ground | R - Body ground | Buzzer output | Ignition switch on (IG), when buzzer not sounding | 6 to 10 V |
| +BS (A26-31) - Body ground | L - Body ground | Solenoid relay power supply | Always | 10 to 14 V |
| GND1 (A26-32) - Body ground | W-B - Body ground | Skid control ECU ground | Always | Below 1 Ω |
| IG1 (A26-46) - Body ground | P - Body ground | IG1 power supply | Ignition switch on (IG) | 10 to 14 V |