HEIGHT CONTROL SENSOR > INSPECTION |
| 1. INSPECT REAR HEIGHT CONTROL SENSOR SUB-ASSEMBLY |
![]() |
Connect the 3 dry cell batteries (1.5 V) in series.
Connect the positive (+) lead from the battery to terminal 3, and the negative (-) lead from the battery to terminal 1.
Measure the voltage between terminals 2 and 1 while slowly moving the link up and down.
| Tester Connection | Condition | Specified Condition |
| 2 (SHRR) - 1 (SHG) | +45°(High) | Approx. 4.05 V |
| 0° (normal) | Approx. 2.25 V | |
| -45°(Low) | Approx. 0.45 V |