DTC B1810/53 Short in Driver Side Squib 2nd Step Circuit |
DTC B1811/53 Open in Driver Side Squib 2nd Step Circuit |
DTC B1812/53 Short to GND in Driver Side Squib 2nd Step Circuit |
DTC B1813/53 Short to B+ in Driver Side Squib 2nd Step Circuit |
| DTC No. | DTC Detecting Condition | Trouble Area |
| B1810/53 |
|
|
| B1811/53 |
|
|
| B1812/53 |
|
|
| B1813/53 |
|
|

| 1.CHECK STEERING PAD (DRIVER SIDE SQUIB 2ND STEP) |
![]() |
Turn the ignition switch to the LOCK position.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Disconnect the connectors from the steering pad.
Connect the white wire side of SST (resistance 2.1 Ω) to connector E (black connector).
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch to the ON position, and wait for at least 60 seconds.
Clear the DTCs stored in the memory (Click here).
Turn the ignition switch to the LOCK position.
Turn the ignition switch to the ON position, and wait for at least 60 seconds.
Check the DTCs (Click here).
|
| ||||
| NG | |
| 2.CHECK CONNECTOR |
Turn the ignition switch to the LOCK position.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Disconnect the SST from connector E.
Check that the spiral cable connectors (on the steering pad side) are not damaged.
|
| ||||
| OK | |
| 3.CHECK DRIVER SIDE SQUIB 2ND STEP CIRCUIT |
![]() |
Disconnect the connectors from the center airbag sensor assembly.
Check for a short to B+ in the circuit.
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch to the ON position.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D2+ - Body ground | ignition switch ON | Below 1 V |
| D2- - Body ground | ignition switch ON | Below 1 V |
Check for an open in the circuit.
Turn the ignition switch to the LOCK position.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D2+ - D2- | Always | Below 1 Ω |
Check for a short to ground in the circuit.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D2+ - Body ground | Always | 1 MΩ or higher |
| D2- - Body ground | Always | 1 MΩ or higher |
Check for a short in the circuit.
Release the activation prevention mechanism built into connector B (Click here).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D2+ - D2- | Always | 1 MΩ or higher |
|
| ||||
| OK | |
| 4.CHECK CENTER AIRBAG SENSOR ASSEMBLY |
![]() |
Connect the connectors to the steering pad and the center airbag sensor assembly.
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch to the ON position, and wait for at least 60 seconds.
Clear the DTCs stored in the memory (Click here).
Turn the ignition switch to the LOCK position.
Turn the ignition switch to the ON position, and wait for at least 60 seconds.
Check the DTCs (Click here).
|
| ||||
| OK | ||
| ||
| 5.CHECK INSTRUMENT PANEL WIRE |
![]() |
Check for a short to B+ in the circuit.
Restore the released activation prevention mechanism of connector B to the original condition.
Disconnect the instrument panel wire connector from the spiral cable.
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch to the ON position.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| E16-4 (D2+) - Body ground | Ignition switch ON | Below 1 V |
| E16-3 (D2-) - Body ground | Ignition switch ON | Below 1 V |
Check for an open in the circuit.
Turn the ignition switch to the LOCK position.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| E16-4 (D2+) - E16-3 (D2-) | Always | Below 1 Ω |
Check for a short to ground in the circuit.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| E16-4 (D2+) - Body ground | Always | 1 MΩ or higher |
| E16-3 (D2-) - Body ground | Always | 1 MΩ or higher |
Check for a short in the circuit.
Release the activation prevention mechanism built into connector B (Click here).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| E16-4 (D2+) - E16-3 (D2-) | Always | 1 MΩ or higher |
|
| ||||
| OK | |
| 6.CHECK SPIRAL CABLE |
![]() |
Check for a short to B+ in the circuit.
Connect the negative (-) terminal cable to the battery, and wait for at least 2 seconds.
Turn the ignition switch to the ON position.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D2+ - Body ground | Ignition switch ON | Below 1 V |
| D2- - Body ground | Ignition switch ON | Below 1 V |
Check for an open in the circuit.
Turn the ignition switch to the LOCK position.
Disconnect the negative (-) terminal cable from the battery, and wait for at least 90 seconds.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D2+ - D2- | Always | Below 1 Ω |
Check for a short to ground in the circuit.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D2+ - Body ground | Always | 1 MΩ or higher |
| D2- - Body ground | Always | 1 MΩ or higher |
Check for a short in the circuit.
Release the activation prevention mechanism built into connector D (Click here).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D2+ - D2- | Always | 1 MΩ or higher |
|
| ||||
| OK | ||
| ||