POWER DOOR LOCK CONTROL SYSTEM > Door Control Switch Circuit |


| 1.READ VALUE USING INTELLIGENT TESTER |
Connect the intelligent tester to the DLC3.
Turn the ignition switch on (IG).
Turn the intelligent tester on.
for LHD:
Enter the following menus: Body / Master Switch / Data List.
Read the Data List according to the display on the intelligent tester.
| Tester Display | Measurement Item / Range | Normal Condition | Diagnostic Note |
| Door Lock Switch Status | Door control switch lock signal/ON or OFF | ON: Door control switch is pushed to lock position OFF: Door control switch is not pushed to lock position | - |
| Door Unlock Switch Status | Door control switch unlock signal/ON or OFF | ON: Door control switch is pushed to unlock position OFF: Door control switch is not pushed to unlock position | - |
for RHD:
Enter the following menus: Body / Main Body / Data List.
Read the Data List according to the display on the intelligent tester.
| Tester Display | Measurement Item / Range | Normal Condition | Diagnostic Note |
| Door Lock SW-Lock | Door control switch lock signal/ON or OFF | ON: Door control switch is pushed to lock position OFF: Door control switch is not pushed to lock position | - |
| Door Lock SW-Unlock | Door control switch unlock signal/ON or OFF | ON: Door control switch is pushed to unlock position OFF: Door control switch is not pushed to unlock position | - |
| Result | Proceed to |
| OK | A |
| NG (for LHD) | B |
| NG (for RHD) | C |
|
| ||||
|
| ||||
| A | ||
| ||
| 2.INSPECT DOOR CONTROL SWITCH ASSEMBLY |
![]() |
Remove the master switch.
Measure the resistance of the door control switch.
| Tester Connection | Switch Condition | Specified Condition |
| 2 - 9 | Lock | Below 1 Ω |
| 2 - 9 | OFF (Free) | 10 kΩ or higher |
| 8 - 9 | Unlock | Below 1 Ω |
| 8 - 9 | OFF (Free) | 10 kΩ or higher |
|
| ||||
| OK | |
| 3.CHECK WIRE HARNESS (DOOR CONTROL SWITCH - MAIN BODY ECU (INSTRUMENT PANEL J/B)) |
![]() |
Disconnect the door control switch connector.
Disconnect the ECU (instrument panel J/B) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| L1-2 - IJ-3 | Always | Below 1 Ω |
| L1-8 - IJ-4 | Always | Below 1 Ω |
| L1-9 - Body ground | Always | Below 1 Ω |
| IJ-3 - Body ground | Always | 10 kΩ or higher |
| IJ-4 - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||