FRONT SPEED SENSOR > INSPECTION |
| 1. INSPECT FRONT SPEED SENSOR (w/o VSC) |
Inspect the front speed sensor. If any of the following occurs, replace the front speed sensor with a new one:
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition |
| 1 (FL+) - 2 (FL-) | 1.4 to 1.8 kΩ at 20 °C (68°F) |
| 1 (FL+) - Body ground | 10 kΩ or higher |
| 2 (FL-) - Body ground | 10 kΩ or higher |
| Tester Connection | Specified Condition |
| 1 (FR+) - 2 (FR-) | 1.4 to 1.8 kΩ at 20 °C (68°F) |
| 1 (FR+) - Body ground | 10 kΩ or higher |
| 2 (FR-) - Body ground | 10 kΩ or higher |
| 2. INSPECT FRONT SPEED SENSOR (w/ VSC) |
Inspect the front speed sensor. If any of the following occurs, replace the front speed sensor with a new one:
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition |
| 1 (FL+) - 2 (FL-) | 1.4 to 1.8 kΩ at 20 °C (68°F) |
| 1 (FL+) - Body ground | 10 kΩ or higher |
| 2 (FL-) - Body ground | 10 kΩ or higher |
| Tester Connection | Specified Condition |
| 1 (FR+) - 2 (FR-) | 1.4 to 1.8 kΩ at 20 °C (68°F) |
| 1 (FR+) - Body ground | 10 kΩ or higher |
| 2 (FR-) - Body ground | 10 kΩ or higher |