METER / GAUGE SYSTEM > FAIL-SAFE CHART |
| Condition | Response | Recovery |
| Engine coolant temperature data is interrupted for 3.1 seconds. | The gauge needle indicates between / and C. | Engine coolant temperature data is received. |
| Condition | Response | Recovery |
| Shift position data is interrupted for 3.1 seconds. | All indicator light go off. | Normal data is received. |
| Gear position data is interrupted for 3 seconds. | The gear position indicator light goes off. | Normal data is received. |
| Condition | Response | Recovery |
| ABS & brake data is interrupted for 1 second. | The warning light comes on. | Normal data is received. |
| Condition | Response | Recovery |
| Each door condition data is interrupted for 10 seconds. | The data received most recently remains indicated. | Normal data is received. |
| Condition | Response | Recovery |
| Driver side front seat inner belt assembly data is interrupted for 10 seconds. | The data received most recently remains indicated. | Normal data is received. |
| Condition | Response | Recovery |
| Regular data is interrupted for 10 seconds. | The data received most recently remains indicated. | Normal data is received. |
| Condition | Response | Recovery |
| Regular data is interrupted for 10 seconds. | The data received most recently remains indicated. | Normal data is received. |
| Condition | Response | Recovery |
| Airbag data is interrupted for 10 seconds. | The warning light comes on. | Normal data is received. |
| Turn the ignition switch to the ON position, then the combination meter (meter CPU) can't detect the voltage of 9 V or more for 60 seconds. |
| Condition | Response | Recovery |
| Regular data is interrupted for 10 seconds. | The data received most recently remains indicated. | Normal data is received. |
| Condition | Response | Recovery |
| Regular data is interrupted for 10 seconds. | The data received most recently remains indicated. | Normal data is received. |
| Condition | Response | Recovery |
| Regular data is interrupted. | The warning light goes off. | Normal data is received. |
| Condition | Response | Recovery |
| Cruise information data is interrupted for 60 seconds. | The display becomes blank (only measurement units are displayed). | Normal data is received. |