Home
›
ENGINE · 2AZ-FE
›
EMISSION CONTROL
›
AIR FUEL RATIO SENSOR
AIR FUEL RATIO SENSOR > INSPECTION
for Preparation
Click here
1. INSPECT AIR FUEL RATIO SENSOR
Using an ohmmeter, measure the resistance between terminals 1 (HT) and 2 (+B).
Standard resistance:
Condition
Specified Condition
20°C (68°F)
1.8 to 3.4 Ω
If the result is not as specified, replace the sensor.