Home › ENGINE · 2AZ-FE › EMISSION CONTROL › HEATED OXYGEN SENSOR

HEATED OXYGEN SENSOR > INSPECTION

for Preparation Click here



1. INSPECT HEATED OXYGEN SENSOR


    A104021E01
  1. Measure the resistance between terminals 1 (HT) and 2 (+B).

    Standard resistance:
    Condition
    Specified Condition
    20°C (68°F)
    11 to 16 Ω

    If the resistance is not as specified, replace the sensor.