Home › TRANSMISSION ยท U660E AUTOMATIC TRANSAXLE › AUTOMATIC TRANSAXLE SYSTEM

AUTOMATIC TRANSAXLE SYSTEM > TERMINALS OF ECU

for Preparation Click here



TCM

C133222E01

HINT:
Each TCM terminal's standard voltage is shown in the table below.
In the table, first follow the information under "Condition". Look under "Symbols (Terminal No.)" for the terminals to be inspected. The standard voltage between the terminals is shown under "Specific Condition".
Use the illustration above as a reference for the TCM terminals.


Symbols (Terminals No.)
Wiring Color
Terminal Description
Condition
Specified Condition
R (C56-15) - E1 (C56-8)
W - B-W
R shift position switch signal
Ignition switch ON and shift lever in R position
10 to 14 V
Ignition switch ON and shift lever in any position except R position
Below 1 V
D (C56-16) - E1 (C56-8)
R - B-W
D shift position switch signal
Ignition switch ON and shift lever in D or 3 position
10 to 14 V
Ignition switch ON and shift lever in any position except D and 3 position
Below 1 V
STP (C56-12) - E1 (C56-8)
B - B-W
Stop light switch signal
Brake pedal is depressed
7.5 to 14 V
Brake pedal is released
Below 1.5 V
NSW (C56-11) - E1 (C56-8)
L - B-W
Park / neutral switch signal
Ignition switch ON and shift lever in P or N position
Below 2 V
Ignition switch ON and shift lever in any position except P or N position
10 to 14 V
STA (C56-10) - E1 (C56-8)
Y - B-W
Starter signal
Cranking (shift lever position in P or N position, ignition switch START)
10 to 14 V
Ignition switch ON and shift lever in any position except P or N position
Below 2 V
SPD1 (C56-3) - E1 (C56-8)
BR - B-W
Speed signal from combination meter
Vehicle speed 12 mph (20 km/h)
Pulse generation
(See waveform 1)
BATT (C56-1) - E1 (C56-8)
W-L - B-W
Battery (for measuring battery voltage and for TCM memory)
Always
9 to 14 V
IG2 (C56-13) - E1 (C56-8)
L-B - B-W
Ignition switch
Ignition switch ON
9 to 14 V
+B (C56-18) - E1 (C56-8)
W-L - B-W
Power source of TCM
Ignition switch ON
9 to 14 V
CAN+ (C56-6) - E1 (C56-8)
B - B-W
CAN communication line
Ignition switch ON
Pulse generation
(See waveform 2)
CAN- (C56-7) - E1 (C56-8)
Y - B-W
CAN communication line
Ignition switch ON
Pulse generation
(See waveform 3)


    G034872E02
  1. Waveform 1
    Reference: 
    Terminal
    SPD1 - E1
    Tool setting
    2 V/DIV, 20 ms./DIV
    Vehicle condition
    Vehicle speed 12 mph (20 km/h)



  2. G036660E06
  3. Waveform 2
    Reference: 
    Terminal
    CAN+ - E1
    Tool setting
    1 V/DIV, 10 ms./DIV
    Vehicle condition
    Engine is stopped, ignition ON



  4. G036661E05
  5. Waveform 3
    Reference: 
    Terminal
    CAN- - E1
    Tool setting
    1 V/DIV, 10 ms./DIV
    Vehicle condition
    Engine is stopped, ignition ON


ECM

HINT:
Each ECM terminal's standard voltage is shown in the table below.
In the table, first follow the information under "Condition". Look under "Symbols (Terminal No.)" for the terminals to be inspected. The standard voltage between the terminals is shown under "Specific Condition".
Use the illustration above as a reference for the ECM terminals.


A107881E43


RHD: 
Symbols (Terminals No.)
Wiring Color
Terminal Description
Condition
Specified Condition
S (A24-25) - E1 (C58-81)
Y - W-B
S shift position switch signal
IG switch ON and shift lever in S position
10 to 14 V
IG switch ON and shift lever in any position except S position
Below 1 V
SFTU (A24-16) - E1 (C58-81)
R - W-B
Up shift switch signal
IG switch ON and shift lever in S position
10 to 14 V
IG switch ON and shift lever in "+" position (Up shift)
Below 1 V
SFTD (A24-51) - E1 (C58-81)
L - W-B
Down shift switch signal
IG switch ON and shift lever in S position
10 to 14 V
IG switch ON and shift lever in "-" position (Down shift)
Below 1 V

LHD: 
Symbols (Terminals No.)
Wiring Color
Terminal Description
Condition
Specified Condition
S (A55-25) - E1 (C55-81)
Y - W-B
S shift position switch signal
IG switch ON and shift lever in S position
10 to 14 V
IG switch ON and shift lever in any position except S position
Below 1 V
SFTU (A55-16) - E1 (C55-81)
R - W-B
Up shift switch signal
IG switch ON and shift lever in S position
10 to 14 V
IG switch ON and shift lever in "+" position (Up shift)
Below 1 V
SFTD (A55-51) - E1 (C55-81)
L - W-B
Down shift switch signal
IG switch ON and shift lever in S position
10 to 14 V
IG switch ON and shift lever in "-" position (Down shift)
Below 1 V