Home › BODY ELECTRICAL › OTHER SYSTEM › CLOCK

CLOCK > ON-VEHICLE INSPECTION

for Preparation Click here



1. INSPECT CLOCK ASSEMBLY


    E128063E02
  1. Disconnect the F3 connector.

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Condition
    Specified Condition
    F3-1 (B) - Body ground
    Always
    10 to 14 V
    F3-2 (ACC) - Body ground
    Turn the ignition switch off
    Below 1 V
    Turn the ignition switch to the ON position
    10 to 14 V

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    F3-19 (GND1) - Body ground
    Always
    Below 1 Ω

    HINT:
    If the value is not as specified, repair or replace the wire harness or connector.