Start the engine and warm it up.
Perform the indicator check (Click here).
Push the "R/F" switch to perform the actuator check.
- HINT:
- Be sure to perform the actuator check after starting the engine.
As the actuator check is repeated from steps 1 to 10 at 1 second intervals, check the temperature and air flow visually and by hand.
- HINT:
- The display blinks at 1 second intervals in the step operation.
- Push the "OFF" switch to finish panel diagnosis.
- Push the "AUTO" switch to enter the sensor check mode.
Step No.
| Display Code
| Conditions
|
Blower Level
| Air Mix Damper
| Airflow Vent
| Air Inlet Damper
| Compressor
|
1
| 0
| 0
| 0% open
| FACE
| FRESH
| OFF
|
2
| 1
| 1
| 0% open
| FACE
| FRESH
| OFF
|
3
| 2
| 17
| 0% open
| FACE
| RECIRCULATION / FRESH
| ON
|
4
| 3
| 17
| 0% open
| FACE
| RECIRCULATION
| ON
|
5
| 4
| 17
| 50% open
| B/L
| RECIRCULATION
| ON
|
6
| 5
| 17
| 50% open
| B/L
| RECIRCULATION
| ON
|
7
| 6
| 17
| 50% open
| FOOT
| FRESH
| ON
|
8
| 7
| 17
| 100% open
| FOOT-0
| FRESH
| ON
|
9
| 8
| 17
| 100% open
| F/D
| FRESH
| ON
|
10
| 9
| 31
| 100% open
| DEF
| FRESH
| ON
|

|
If the steps are difficult to read because they change automatically, push the "MODE" switch to display the steps one at a time so that they can be read easily. The items are displayed step by step each time the "MODE" switch is pushed.
- HINT:
- Push the "OFF" switch to finish panel diagnosis.
- Push the "R/F" switch to enter the sensor check mode.