POWER DOOR LOCK CONTROL SYSTEM > Door Key Lock / Unlock Switch Circuit |


| 1.INSPECT FRONT DOOR LOCK ASSEMBLY RH (DOOR KEY LOCK AND UNLOCK SWITCH) |
![]() |
Inspect LHD models.
Remove the front door lock assembly RH.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 5 - 8 | ON (Door lock set to UNLOCK) | Below 1 Ω |
| 5 - 8 6 - 8 | OFF (Free) | 10 kΩ or higher |
| 6 - 8 | ON (Door lock set to LOCK) | Below 1 Ω |
![]() |
Inspect RHD models.
Remove the front door lock assembly LH.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 7 - 9 | ON (Door lock set to LOCK) | Below 1 Ω |
| 7 - 9 7 - 10 | OFF (Free) | 10 kΩ or higher |
| 7 - 10 | ON (Door lock set to UNLOCK) | Below 1 Ω |
|
| ||||
| OK | |
| 2.CHECK WIRE HARNESS (FRONT DOOR LOCK RH - MAIN BODY ECU (INSTRUMENT PANEL J/B)) |
Disconnect the IJ J/B connector.

Measure the resistance according to the value(s) in the table below.
| Tester Connection (Symbols) | Condition | Specified Condition |
|
(*1) M8-6 (L) - IJ-5 | Always | Below 1 Ω |
|
(*1) M8-5 (UL) - IK-7 | Always | Below 1 Ω |
|
(*1) M8-8 (E) - Body ground | Always | Below 1 Ω |
|
(*1) M8-6 (L) - Body ground | Always | 10 kΩ or higher |
|
(*1) M8-5 (UL) - Body ground | Always | 10 kΩ or higher |
|
(*2) I7-9 (L) - IK-16 | Always | Below 1 Ω |
|
(*2) I7-10 (UL) - IJ-7 | Always | Below 1 Ω |
|
(*2) I7-7 (E) - Body ground | Always | Below 1 Ω |
|
(*2) I7-9 (L) - Body ground | Always | 10 kΩ or higher |
|
(*2) I7-10 (UL) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||