Home › ENGINE ยท 2GR-FE › EXHAUST › EXHAUST PIPE

EXHAUST PIPE > REMOVAL

for Preparation Click here



1. REMOVE EXHAUST TAIL PIPE ASSEMBLY


  1. Remove the 4 nuts and 2 exhaust tail pipes.


    A135718

  1. Remove the 2 gaskets from the exhaust tail pipes.



2. REMOVE EXHAUST CENTER PIPE ASSEMBLY


  1. Remove the 2 bolts, 2 nuts and exhaust center pipe assembly.


    A135719

  1. Remove the gasket from the exhaust center pipe assembly.



3. REMOVE FRONT EXHAUST PIPE NO. 1 SUPPORT BRACKET


    A085549E01
  1. Remove the 2 nuts and front support brackets.



4. REMOVE EXHAUST FRONT PIPE ASSEMBLY
  1. Disconnect the 2 heated oxygen sensor (bank 1, 2 sensor 2) connectors.



  1. Remove the 2 nuts from the exhaust front pipe (left bank exhaust manifold side).


    A135720

  1. Remove the 2 nuts from the exhaust front pipe (right bank exhaust pipe manifold side).

  1. Remove the exhaust front pipe.

  1. Remove the 2 gaskets from the exhaust front pipe.



5. REMOVE HEATED OXYGEN SENSOR (for Bank 1)


    A135716E01
  1. Using SST, remove the oxygen sensor.

    SST
    09224-00010  



6. REMOVE HEATED OXYGEN SENSOR (for Bank 2)


    A135724E01
  1. Using SST, remove the oxygen sensor.

    SST
    09224-00010  



7. REMOVE REAR EXHAUST PIPE NO. 1 SUPPORT BRACKET


    A132948E01
  1. Remove the 2 bolts and rear support bracket.