DTC B2271 Ignition Hold Monitor Malfunction |
| DTC No. | DTC Detection Condition | Trouble Area |
| B2271 | Hold circuit, IG1 relay actuation circuit or IG2 relay actuation circuit inside main body ECU is open or shorted |
|

| 1.CHECK DTC OUTPUT |
Clear the DTCs (Click here).
Check for DTCs again.
|
| ||||
| OK | ||
| ||
| 2.INSPECT FUSE (AM2) |
Remove the AM2 fuse from the engine room J/B.
Measure the resistance of the fuse.
| Tester Connection | Condition | Specified Condition |
| AM2 fuse | Always | Below 1 Ω |
|
| ||||
| OK | |
| 3.CHECK WIRE HARNESS (MAIN BODY ECU - BATTERY) |
![]() |
Disconnect the E6 and E7 ECU connectors.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| E7-6 (AM1) - Body ground | Always | 11 to 14 V |
| E6-1 (AM2) - Body ground | Always | 11 to 14 V |
|
| ||||
| OK | ||
| ||