DTC B1411/11 Room Temperature Sensor Circuit |
| DTC No. | DTC Detection Condition | Trouble Area |
| B1411/11 | Room temperature sensor circuit (Open or short) |
|

| 1.READ VALUE USING INTELLIGENT TESTER |
Connect the intelligent tester to the DLC3.
Turn the ignition switch to the ON position and turn the intelligent tester main switch on.
Select the item below in the Data List, and read the display on the intelligent tester.
| Item | Measurement Item / Display (Range) | Normal Condition | Diagnostic Note |
| Room Temperature Sensor (Room Temp) | Room temperature sensor / min.: -6.5°C (20.3°F), max.: 57.25°C (135.05°F) | Actual cabin temperature is displayed | - |
| Result | Proceed to |
| NG | A |
| OK (When troubleshooting according to the PROBLEM SYMPTOMS TABLE) | B |
| OK (When troubleshooting according to the DTC) | C |
|
| ||||
|
| ||||
| A | |
| 2.INSPECT AIR CONDITIONING AMPLIFIER |
![]() |
Remove the A/C amplifier with the connectors still connected.
Turn the ignition switch to the ON position.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| E38-29 (TR) - E38-34 (SG-1) | Ignition switch: ON at 25°C (77°F) | 1.35 to 1.75 V |
| E38-29 (TR) - E38-34 (SG-1) | Ignition switch: ON at 40°C (104°F) | 0.9 to 1.2 V |
| Result | Proceed to |
| NG | A |
| OK (When troubleshooting according to the PROBLEM SYMPTOMS TABLE) | B |
| OK (When troubleshooting according to the DTC) | C |
|
| ||||
|
| ||||
| A | |
| 3.INSPECT A/C ROOM TEMPERATURE SENSOR |
![]() |
Remove the A/C room temperature sensor.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| E27-1 - E27-2 | 10°C (50°F) | 3.00 to 3.73 kΩ |
| E27-1 - E27-2 | 15°C (59°F) | 2.45 to 2.88 kΩ |
| E27-1 - E27-2 | 20°C (68°F) | 1.95 to 2.30 kΩ |
| E27-1 - E27-2 | 25°C (77°F) | 1.60 to 1.80 kΩ |
| E27-1 - E27-2 | 30°C (86°F) | 1.28 to 1.47 kΩ |
| E27-1 - E27-2 | 35°C (95°F) | 1.00 to 1.22 kΩ |
| E27-1 - E27-2 | 40°C (104°F) | 0.80 to 1.00 kΩ |
| E27-1 - E27-2 | 45°C (113°F) | 0.65 to 0.85 kΩ |
| E27-1 - E27-2 | 50°C (122°F) | 0.50 to 0.70 kΩ |
| E27-1 - E27-2 | 55°C (131°F) | 0.44 to 0.60 kΩ |
| E27-1 - E27-2 | 60°C (140°F) | 0.36 to 0.50 kΩ |
|
| ||||
| OK | |
| 4.CHECK HARNESS AND CONNECTOR (A/C ROOM TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER) |
![]() |
Disconnect the connector from the A/C amplifier.
![]() |
Disconnect the connector from the A/C room temperature sensor.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| E38-29 (TR) - E27-1 | Always | Below 1 Ω |
| E38-34 (SG-1) - E27-2 | Always | Below 1 Ω |
| E38-29 (TR) - Body ground | Always | 10 kΩ or higher |
| E38-34 (SG-1) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||