Home › ENGINE · 2GR-FE › EMISSION CONTROL › AIR FUEL RATIO SENSOR

AIR FUEL RATIO SENSOR > INSPECTION

for Preparation Click here



1. INSPECT AIR FUEL RATIO SENSOR


    A075325E04
  1. Measure the resistance between terminals 1 (HT) and 2 (+B).

    Standard resistance:
    Condition
    Specified Condition
    20 °C (68°F)
    1.8 to 3.4 Ω

    If the result is not as specified, replace the sensor.