Home
›
ENGINE · 2GR-FE
›
EMISSION CONTROL
›
HEATED OXYGEN SENSOR
HEATED OXYGEN SENSOR > INSPECTION
for Preparation
Click here
1. INSPECT HEATED OXYGEN SENSOR
Measure the resistance between terminals 1 (HT) and 2 (+B).
Standard resistance:
Condition
Specified Condition
20°C (68°F)
11 to 16 Ω