Home › BODY ELECTRICAL › DOOR LOCK › FRONT DOOR LOCK

FRONT DOOR LOCK > INSPECTION

for Preparation Click here



1. INSPECT FRONT DOOR LOCK LH ASSEMBLY
  1. Remove the front door lock assembly LH.



    B065427E20
  1. Check operation of the door lock motor.

    1. Apply battery voltage and check operation of the door lock motor.

      OK:
      Measurement Condition
      Specified Condition
      Battery positive (+) → Terminal 4
      Battery negative (-) → Terminal 1
      Lock
      Battery positive (+) → Terminal 1
      Battery negative (-) → Terminal 4
      Unlock



    B065428E11
  1. Check operation of the door key lock and unlock switch.

    1. Measure the resistance according to the value(s) in the table below.

      Standard resistance:
      Tester Connection
      Condition
      Specified Condition
      7 - 9
      ON (Door lock set to LOCK)
      Below 1 Ω
      7 - 9
      7 - 10
      OFF (Free)
      10 kΩ or higher
      7 - 10
      ON (Door lock set to UNLOCK)
      Below 1 Ω



    B065427E20
  1. Check operation of the door unlock detection switch.

    1. Measure the resistance according to the value(s) in the table below.

      Standard resistance:
      Tester Connection
      Measurement Condition
      Door Lock Condition
      Specified Condition
      7 - 8
      Battery positive (+) → Terminal 4
      Battery negative (-) → Terminal 1
      Lock
      10 kΩ or higher
      7 - 8
      Battery positive (+) → Terminal 1
      Battery negative (-) → Terminal 4
      Unlock
      Below 1 Ω



2. INSPECT FRONT DOOR LOCK RH ASSEMBLY
  1. Remove the front door lock assembly RH.



    B065429E21
  1. Check operation of the door lock motor.

    1. Apply battery voltage and check operation of the door lock motor.

      OK:
      Measurement Condition
      Specified Condition
      Battery positive (+) → Terminal 4
      Battery negative (-) → Terminal 1
      Lock
      Battery positive (+) → Terminal 1
      Battery negative (-) → Terminal 4
      Unlock



    B112613E01
  1. Check operation of the door key lock and unlock switch.

    1. Measure the resistance according to the value(s) in the table below.

      Standard resistance:
      Tester Connection
      Condition
      Specified Condition
      5 - 8
      ON
      (Door lock set to UNLOCK)
      Below 1 Ω
      5 - 8
      6 - 8
      OFF (Free)
      10 kΩ or higher
      6 - 8
      ON
      (Door lock set to LOCK)
      Below 1 Ω



    B065429E21
  1. Check operation of the door unlock detection switch.

    1. Measure the resistance according to the value(s) in the table below.

      Standard resistance:
      Tester Connection
      Measurement Condition
      Door Lock Condition
      Specified Condition
      7 - 8
      Battery positive (+) → Terminal 4
      Battery negative (-) → Terminal 1
      Lock
      10 kΩ or higher
      7 - 8
      Battery positive (+) → Terminal 1
      Battery negative (-) → Terminal 4
      Unlock
      Below 1 Ω