Home › BODY ELECTRICAL › DOOR LOCK › ENTRY LOCK AND UNLOCK SWITCH

ENTRY LOCK AND UNLOCK SWITCH > INSPECTION

for Preparation Click here



1. INSPECT FRONT DOOR OUTSIDE HANDLE ASSEMBLY LH


    B219217E03
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection (Symbols)
    Condition
    Specified Condition
    1 (TRG-) - 3 (TRG+)
    Lock switch not pushed
    10 kΩ or higher
    1 (TRG-) - 3 (TRG+)
    Lock switch pushed
    Below 1 Ω

    If the result is not specified, replace the front door outside handle assembly LH.



2. INSPECT FRONT DOOR OUTSIDE HANDLE ASSEMBLY RH


    B219216E03
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection (Symbols)
    Condition
    Specified Condition
    1 (TRG-) - 3 (TRG+)
    Lock switch not pushed
    10 kΩ or higher
    1 (TRG-) - 3 (TRG+)
    Lock switch pushed
    Below 1 Ω

    If the result is not specified, replace the front door outside handle assembly RH.