Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › EVAPORATOR TEMPERATURE SENSOR

EVAPORATOR TEMPERATURE SENSOR > ON-VEHICLE INSPECTION

for Preparation Click here



1. INSPECT EVAPORATOR TEMPERATURE SENSOR


    E124474E02
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    5 - 6
    -10°C (14°F)
    7.30 to 9.10 kΩ
    5 - 6
    -5°C (23°F)
    5.65 to 6.95 kΩ
    5 - 6
    0°C (32°F)
    4.40 to 5.35 kΩ
    5 - 6
    5°C (41°F)
    3.40 to 4.15 kΩ
    5 - 6
    10°C (50°F)
    2.70 to 3.25 kΩ
    5 - 6
    15°C (59°F)
    2.14 to 2.58 kΩ
    5 - 6
    20°C (68°F)
    1.71 to 2.05 kΩ
    5 - 6
    25°C (77°F)
    1.38 to 1.64 kΩ
    5 - 6
    30°C (86°F)
    1.11 to 1.32 kΩ

    NOTICE:
    1. Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
    2. When measuring, the sensor temperature must be the same as the ambient temperature.

    HINT:
    As the temperature increases, the resistance decreases (see the graph).

    If the resistance is not as specified, replace the evaporator temperature sensor.