ENTRY AND START SYSTEM > Power Source Mode does not Change to ON (ACC) |

| 1.INSPECT FUSE (AM2) |
Remove the AM2 fuse from the engine room J/B.
Measure the resistance of the fuse.
| Tester Connection | Condition | Specified Condition |
| AM2 fuse | Always | Below 1 Ω |
|
| ||||
| OK | |
| 2.CHECK CONNECTORS |
Check that the connectors are securely connected and the terminals are not deformed or loose.
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (MAIN BODY ECU - BATTERY) |
![]() |
Disconnect the E6 and E7 ECU connectors.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| E7-6 (AM1) - Body ground | Always | 11 to 14 V |
| E6-1 (AM2) - Body ground | Always | 11 to 14 V |
|
| ||||
| OK | |
| 4.CHECK HARNESS AND CONNECTOR (MAIN BODY ECU - BODY GROUND) |
![]() |
Disconnect the IF and IM ECU connectors.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| IF-10 (GND1) - Body ground | Always | Below 1 Ω |
| IM-9 (GND2) - Body ground | Always | Below 1 Ω |
|
| ||||
| OK | |
| 5.INSPECT RELAY (ACC RELAY) |
![]() |
Remove the ACC relay from the instrument panel J/B.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Always | Specified Condition |
| 3 - 5 | When battery voltage is not applied to terminals 1 and 2 | 10 kΩ or higher |
| 3 - 5 | When battery voltage is applied to terminals 1 and 2 | Below 1 Ω |
|
| ||||
| OK | |
| 6.CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL J/B - MAIN BODY ECU) |
Disconnect the E7 ECU connector.

Disconnect the II J/B connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| II-3 - E7-22 (ACCD) | Always | Below 1 Ω |
| E7-22 (ACCD) or II-3 - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | |
| 7.CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL J/B - BATTERY AND BODY GROUND) |
![]() |
Disconnect the IF and IA J/B connectors.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| IF-10 - Body ground | Always | Below 1 Ω |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| IA-1 - Body ground | Always | 11 to 14 V |
|
| ||||
| OK | |
| 8.INSPECT INSTRUMENT PANEL J/B |
Measure the resistance according to the value(s) in the table below.

| Tester Connection | Condition | Specified Condition |
| ACC relay terminal 1 - IF-10 | Always | Below 1 Ω |
| ACC relay terminal 2 - II-3 | Always | Below 1 Ω |
| IF-10 - Body ground | Always | 10 kΩ or higher |
| II-3 - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||