STARTER > INSTALLATION |
| 1. INSTALL STARTER ASSEMBLY (for Manual Transaxle) |
![]() |
Install the starter assembly and clutch flexible hose bracket with the 3 bolts.
![]() |
Connect the wire harness to terminal 30 and install the nut. Then, attach the terminal cap.
Connect the terminal 50 connector to the starter assembly.
| 2. INSTALL STARTER ASSEMBLY (for Automatic Transaxle) |
![]() |
Install the starter assembly with the 2 bolts.
![]() |
Connect the wire harness to terminal 30 and install the nut. Then, attach the terminal cap.
Connect the terminal 50 connector to the starter assembly.
| 3. INSTALL AIR CLEANER CASE SUB-ASSEMBLY |
![]() |
Install the air cleaner case with the 3 bolts.
Connect the hose clamp.
| 4. INSTALL AIR CLEANER CAP SUB-ASSEMBLY |
Install the air cleaner filter element onto the air cleaner case.
![]() |
Insert the hinges. Install the air cleaner cap sub-assembly with the 2 bolts.
![]() |
Align the matchmarks of the No. 1 air cleaner hose and throttle body, and then connect the air cleaner hose No. 1 to the throttle body and unfasten the No. 1 air cleaner hose clamp.
![]() |
Connect the No. 2 ventilation hose to the air cleaner hose.
![]() |
Connect the purge line hose to the clamp (*1).
Connect the 2 purge VSV vacuum hoses (*2).
Connect the purge VSV connector (*3).
Connect the mass air flow meter connector (*4).
| 5. INSTALL AIR CLEANER INLET ASSEMBLY |
![]() |
Install the air cleaner inlet with the 2 bolts.
| 6. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL |