STARTER > REMOVAL |
| 1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL |
| 2. REMOVE AIR CLEANER INLET ASSEMBLY |
![]() |
Remove the 2 bolts, clamp and air cleaner inlet.
| 3. REMOVE AIR CLEANER CAP SUB-ASSEMBLY |
![]() |
Disconnect the mass air flow meter connector (*1).
Disconnect the purge VSV connector (*2).
Disconnect the 2 purge VSV vacuum hoses (*3).
Disconnect the purge line hose from the clamp (*4).
![]() |
Disconnect the No. 2 ventilation hose from the air cleaner hose.
![]() |
Lock the No. 1 air cleaner hose clamp, and then disconnect the No. 1 air cleaner hose from the throttle body.
![]() |
Remove the 2 bolts and air cleaner cap.
Remove the air cleaner filter element from the air cleaner case.
| 4. REMOVE AIR CLEANER CASE SUB-ASSEMBLY |
![]() |
Disconnect the hose clamp.
Remove the 3 bolts and air cleaner case.
| 5. REMOVE STARTER ASSEMBLY (for Manual Transaxle) |
![]() |
Disconnect the terminal 50 connector from the starter assembly.
Remove the nut and disconnect the wire harness from terminal 30.
![]() |
Remove the 3 bolts, clutch flexible hose bracket and starter assembly.
| 6. REMOVE STARTER ASSEMBLY (for Automatic Transaxle) |
![]() |
Disconnect the terminal 50 connector from the starter assembly.
Remove the nut and disconnect the wire harness from terminal 30.
![]() |
Remove the 2 bolts and starter assembly.