Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › ROOM TEMPERATURE SENSOR

ROOM TEMPERATURE SENSOR > INSTALLATION

for Preparation Click here



1. INSTALL ROOM TEMPERATURE SENSOR


    E129986
  1. Engage the claw to install the sensor.

  1. Connect the connector and attach the air hose.



2. INSTALL LOWER INSTRUMENT PANEL FINISH PANEL LH


    B147263E01
  1. Install the air hose and connect the connector.

  1. Engage the 2 claws and the DLC3.

  1. Engage the claw and the 4 clips.

  1. Instal the lower instrument panel finish panel LH with the screw <B> and bolt <A>.



3. INSTALL COWL SIDE TRIM SUB-ASSEMBLY LH


    B132116E01
  1. Engage the 2 clips.

  1. Install the cowl side trim sub-assembly LH with the cowl side trim clip.



4. INSTALL FRONT DOOR SCUFF PLATE LH


    B132067
  1. Engage the 7 claws and 3 clips, then install the front door scuff plate LH.