Home › TRANSMISSION · U660E AUTOMATIC TRANSAXLE › SHIFT SOLENOID VALVE

SHIFT SOLENOID VALVE > INSPECTION

for Preparation Click here



1. INSPECT SHIFT SOLENOID VALVE SL


    C133217
  1. Measure the resistance according to the value(s) in the table below.
    Standard resistance 
    Tester Connection
    Specified Condition
    20°C (68°F)
    Solenoid Connector (SL) - Solenoid Body (SL)
    11 to 15 Ω
    If the value is not as specified, replace the shift solenoid valve.



    C133218
  1. Connect the positive (+) lead to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the shift solenoid valve.

    OK:
    The solenoid makes an operating noise.

    If the operation is not as specified, replace the shift solenoid valve.



2. INSPECT SHIFT SOLENOID VALVE SLT


    G020767E08
  1. Measure the resistance according to the value(s) in the table below.
    Standard resistance 
    Tester Connection
    Specified Condition
    20°C (68°F)
    1 - 2
    5.0 to 5.6 Ω
    If the value is not as specified, replace the shift solenoid valve.

  1. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the shift solenoid valve.

    OK:
    The solenoid makes an operating noise.

    If the operation is not as specified, replace the shift solenoid valve.



3. INSPECT SHIFT SOLENOID VALVE SLU


    G020767E09
  1. Measure the resistance according to the value(s) in the table below.
    Standard resistance 
    Tester Connection
    Specified Condition
    20°C (68°F)
    1 - 2
    5.0 to 5.6 Ω
    If the value is not as specified, replace the shift solenoid valve.

  1. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the shift solenoid valve.

    OK:
    The solenoid makes an operating noise.

    If the operation is not as specified, replace the shift solenoid valve.



4. INSPECT SHIFT SOLENOID VALVE SL2


    G020767E07
  1. Measure the resistance according to the value(s) in the table below.
    Standard resistance 
    Tester Connection
    Specified Condition
    20°C (68°F)
    1 - 2
    5.0 to 5.6 Ω
    If the value is not as specified, replace the shift solenoid valve.

  1. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the shift solenoid valve.

    OK:
    The solenoid makes an operating noise.

    If the operation is not as specified, replace the shift solenoid valve.



5. INSPECT SHIFT SOLENOID VALVE SL1


    G020767E05
  1. Measure the resistance according to the value(s) in the table below.
    Standard resistance 
    Tester Connection
    Specified Condition
    20°C (68°F)
    1 - 2
    5.0 to 5.6 Ω
    If the value is not as specified, replace the shift solenoid valve.

  1. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the shift solenoid valve.

    OK:
    The solenoid makes an operating noise.

    If the operation is not as specified, replace the shift solenoid valve.



6. INSPECT SHIFT SOLENOID VALVE SL3


    G020767E29
  1. Measure the resistance according to the value(s) in the table below.
    Standard resistance 
    Tester Connection
    Specified Condition
    20°C (68°F)
    1 - 2
    5.0 to 5.6 Ω
    If the value is not as specified, replace the shift solenoid valve.

  1. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the shift solenoid valve.

    OK:
    The solenoid makes an operating noise.

    If the operation is not as specified, replace the shift solenoid valve.



7. INSPECT SHIFT SOLENOID VALVE SL4


    G020767E29
  1. Measure the resistance according to the value(s) in the table below.
    Standard resistance 
    Tester Connection
    Specified Condition
    20°C (68°F)
    1 - 2
    5.0 to 5.6 Ω
    If the value is not as specified, replace the shift solenoid valve.

  1. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the shift solenoid valve.

    OK:
    The solenoid makes an operating noise.

    If the operation is not as specified, replace the shift solenoid valve.