Home › BODY ELECTRICAL › OTHER SYSTEM › CLOCK

CLOCK > Power Source Circuit

for Preparation Click here


DESCRIPTION

This circuit is the power source for the clock assembly. This circuit provides two types of power sources; one is a constant power source mainly used as a backup power source, and the other is a power source mainly used for signal transmission. The constant power source is mainly used as a backup power source of the clock assembly, however, it is also used for communication.

HINT:
If the clock assembly displays "1:00" when the ignition switch turned off, and turned to the ON position again, the B terminal has a malfunction.


WIRING DIAGRAM


E132651E02


INSPECTION PROCEDURE

1.INSPECT CLOCK ASSEMBLY


    E128063E05
  1. Disconnect the F3 connector.

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Condition
    Specified Condition
    F3-1 (B) - Body ground
    Always
    10 to 14 V
    F3-2 (ACC) - Body ground
    Turn the ignition switch to the ON position
    10 to 14 V

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    F3-19 (GND1) - Body ground
    Always
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

PROCEED TO NEXT INSPECTION PROCEDURE SHOWN IN PROBLEM SYMPTOMS TABLE