COMPRESSOR AND MAGNETIC CLUTCH (for 2GR-FE) > INSPECTION |
| 1. INSPECT COMPRESSOR AND MAGNETIC CLUTCH (A/C LOCK SENSOR) |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | Always (at 20°C (68°F)) | 160 to 320 Ω |
| 2. INSPECT COMPRESSOR AND MAGNETIC CLUTCH (A/C COMPRESSOR SOLENOID) |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 2 - 1 | 20°C (68°F) | 10 to 11 Ω |
| 3. INSPECT COMPRESSOR AND MAGNETIC CLUTCH |
![]() |
Disconnect the connector from the compressor and magnetic clutch.
![]() |
Disconnect the connector from the magnetic clutch.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A-3 - B-1 | Always | Below 1 Ω |
| A-3 - Body ground | Always | 10 kΩ or higher |
| 4. INSPECT MAGNETIC CLUTCH |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 - Body ground | Always | 3.4 to 3.8 Ω |
When connector terminal 1 is connected to the positive (+) battery terminal, check that the following occurs: 1) the magnetic clutch's operating sound can be heard, and 2) the magnetic clutch's hub and rotor lock.