Home › ENGINE · 2GR-FE › ENGINE CONTROL SYSTEM › IGNITION RELAY NO. 2

IGNITION RELAY NO. 2 > INSPECTION

for Preparation Click here



1. INSPECT IGNITION RELAY NO. 2


    B016200
  1. Using an ohmmeter, measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Specified Condition
    3 - 5
    10 kΩ or higher
    3 - 5
    Below 1 Ω (Battery voltage applied between terminals 1 and 2)