Home › SERVICE SPECIFICATIONS › SERVICE SPECIFICATIONS › BRAKE CONTROL

BRAKE CONTROL > SERVICE DATA



Front speed sensor
Without VSC
LH
1 (FL+) - 2 (FL-)
Always
1.4 to 1.8 kΩ at 20 °C (68 °F)
1 (FL+) - Body ground
Always
10 kΩ or higher
2 (FL-) - Body ground
Always
10 kΩ or higher
RH
1 (FR+) - 2 (FR-)
Always
1.4 to 1.8 kΩ at 20 °C (68 °F)
1 (FR+) - Body ground
Always
10 kΩ or higher
2 (FR-) - Body ground
Always
10 kΩ or higher
with VSC
LH
1 (FL+) - 2 (FL-)
Always
1.4 to 1.8 kΩ at 20 °C (68 °F)
1 (FL+) - Body ground
Always
10 kΩ or higher
2 (FL-) - Body ground
Always
10 kΩ or higher
RH
1 (FR+) - 2 (FR-)
Always
1.4 to 1.8 kΩ at 20°C (68 °F)
1 (FR+) - Body ground
Always
10 kΩ or higher
2 (FR-) - Body ground
Always
10 kΩ or higher
Skid control sensor
Without VSC
LH
1 (RR+) - 2 (RR-)
Always
Below 2.2 kΩ
1 (RR+) - Body ground
Always
10 kΩ or higher
2 (RR-) - Body ground
Always
10 kΩ or higher
RH
1 (RL+) - 2 (RL-) Below
Always
Below 2.2 kΩ
1 (RL+) - Body ground 10
Always
10 kΩ or higher
2 (RL-) - Body ground
Always
10 kΩ or higher
With VSC
LH
2 (RL+) - 1 (RL-)
Always
0.9 to 2.1 kΩ
2 (RL+) - Body ground
Always
10 kΩ or higher
1 (RL-) - Body ground
Always
10 kΩ or higher
RH
2 (RR+) - 1 (RR-)
Always
0.9 to 2.1 kΩ
2 (RR+) - Body ground
Always
10 kΩ or higher
1 (RR-) - Body ground
Always
10 kΩ or higher
VSC NO. 1 (Fail Safe) relay


Resistance 3 - 5
Always
10 kΩ or higher
Resistance 3 - 5
Apply B+ between terminals 1 and 2
Below 1 Ω
VSC NO. 1 relay


Resistance 3 - 5
Always
10 kΩ or higher
Resistance 3 - 5
Apply B+ between terminals 1 and 2
Below 1 Ω