Home › BODY ELECTRICAL › PARK ASSIST / MONITORING › CLEARANCE SONAR MAIN SWITCH

CLEARANCE SONAR MAIN SWITCH > INSPECTION

for Preparation Click here



1. INSPECT CLEARANCE SONAR MAIN SWITCH


    E159911E01
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Condition
    Condition
    specified Condition
    E66-1 - E66-3
    Always
    10 kΩ or higher
    E66-1 - E66-3
    Always
    Below 1 Ω

    If the result is not as specified, replace the Clearance sonar main switch.