Home › BODY ELECTRICAL › PARK ASSIST / MONITORING › ULTRASONIC SENSOR (for Front Side)

ULTRASONIC SENSOR (for Front Side) > INSPECTION

for Preparation Click here



1. INSPECT NO. 1 ULTRASONIC SENSOR


    E159935E05
  1. Measure the resistance of the sensor.

    Standard Resistance:
    Tester Condition
    Condition
    specified Condition
    1 (S) - 2 (E)
    Always
    600 to 1200 kΩ

    If the result is not as specified, replace the No. 1 ultrasonic sensor.

    NOTICE:
    Set the tester to the 100 kΩ range before performing the measurement.