DTC P0100 Mass or Volume Air Flow Circuit |
DTC P0102 Mass or Volume Air Flow Circuit Low Input |
DTC P0103 Mass or Volume Air Flow Circuit High Input |

| DTC No. | DTC Detection Condition | Trouble Area |
| P0100 | Open or short in mass air flow meter sub-assembly circuit for 3 seconds (1 trip detection logic) |
|
| P0102 | Mass air flow meter sub-assembly voltage is less than 0.2 V for 3 seconds (1 trip detection logic) |
|
| P0103 | Mass air flow meter sub-assembly voltage is more than 4.9 V for 3 seconds (1 trip detection logic) |
|
| Mass Air Flow Rate (gm/sec) | Malfunction |
| Approximately 0.0 |
|
| 271.0 or more |
|

| 1.READ DTC OUTPUT |
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the tester on.
Enter the following menus: Powertrain / Engine and ECT / DTC.
Read the DTCs.
| Result | Proceed to |
| DTC P0100 and P0102 or P0102 are output | A |
| DTC P0100 and P0103 or P0103 are output | B |
|
| ||||
| A | |
| 2.CHECK HARNESS AND CONNECTOR (POWER SOURCE VOLTAGE) |
![]() |
Disconnect the mass air flow meter sub-assembly connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| C2-3 (+B) - Body ground | Ignition switch ON | 11 to 14 V |
| *1 | Front view of wire harness connector (to Mass Air Flow Meter Sub-assembly) |
Reconnect the mass air flow meter sub-assembly connector.
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER SUB-ASSEMBLY - ECM) |
Disconnect the mass air flow meter sub-assembly connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| C2-5 (VG) - C24-118 (VG) | Always | Below 1 Ω |
| C2-4 (E2G) - C24-116 (E2G) | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
| C2-5 (VG) or C24-118 (VG) - Body ground | Always | 10 kΩ or higher |
Reconnect the mass air flow meter sub-assembly connector.
Reconnect the ECM connector.
|
| ||||
| OK | |
| 4.INSPECT MASS AIR FLOW METER SUB-ASSEMBLY |
Perform On-vehicle Inspection (Click here).
Inspect the function of the mass air flow meter sub-assembly.
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the tester to on.
Enter the following menus: Powertrain / Engine and ECT / Data List / All Data / MAF.
Start the engine.
Check that the reading of the MAF changes when the engine is raced.
|
| ||||
| OK | ||
| ||
| 5.CHECK HARNESS AND CONNECTOR (SENSOR GROUND) |
Disconnect the mass air flow meter sub-assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| C2-4 (E2G) - Body ground | Always | Below 1 Ω |
Reconnect the mass air flow meter sub-assembly connector.
|
| ||||
| OK | ||
| ||
| 6.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER SUB-ASSEMBLY - ECM) |
Disconnect the mass air flow meter sub-assembly connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| C2-4 (E2G) - C24-116 (E2G) | Always | Below 1 Ω |
Reconnect the mass air flow meter sub-assembly connector.
Reconnect the ECM connector.
|
| ||||
| OK | ||
| ||