Home › Engine / Hybrid System › 2AR-FE ENGINE CONTROL › SFI SYSTEM
NM19V0EQ _51 Engine / Hybrid System _014243 2AR-FE ENGINE CONTROL _0072842 SFI SYSTEM DE DETAILS F

2AR-FE ENGINE CONTROL  SFI SYSTEM  DETAILS  AIR FUEL RATIO SENSOR  


CONSTRUCTION


a.

A planar type air fuel ratio sensor and a cup type oxygen sensor are used. The basic construction of the oxygen sensor and the air fuel ratio sensor is the same. However, they are divided into the cup type and the planar type, according to the different types of heater construction used.


b.

The planar type air fuel ratio sensor uses alumina, which excels in heat conductivity and electrical insulation, to integrate a sensor element with a heater, thus improving the warm-up performance of the sensor.

W104455
0.823,0.104 3.792,3.531 2.969,3.427 3.854,0.104 6.823,3.531 2.969,3.427 2.635,1.938 2.094,1.938 true 2.573,2.208 2.042,2.208 true 2.51,1.646 2.51,1.26 2.51,1.26 2.073,1.26 true 3.5,1.771 2.958,1.771 true 2.719,1.927 2.719,1.167 2.719,1.167 3.521,1.167 true 2.906,2.479 3.5,2.479 true 2.552,2.542 2.552,2.99 2.552,2.99 3.417,2.99 true 5.563,2.104 5.021,2.104 true 6.448,2.135 6.167,2.135 true 6,1.865 6,1.583 6,1.583 6.333,1.583 true 5.875,2.104 5.875,1.365 5.875,1.365 6.167,1.365 true 5.635,1.865 5.635,1.135 5.635,1.135 5.927,1.135 true 1.896,1.854 2.083,2.031 0.188,0.177 10 *3 1.854,2.125 2.042,2.302 0.188,0.177 10 *5 1.885,1.167 2.073,1.344 0.188,0.177 10 *4 3.552,1.677 3.74,1.854 0.188,0.177 10 *4 3.552,1.083 3.74,1.26 0.188,0.177 10 *6 3.542,2.396 3.729,2.573 0.188,0.177 10 *7 3.458,2.906 3.646,3.083 0.188,0.177 10 *8 4.854,2.031 5.042,2.208 0.188,0.177 10 *3 6.49,2.052 6.677,2.229 0.188,0.177 10 *3 6.427,1.51 6.615,1.688 0.188,0.177 10 *6 6.208,1.281 6.396,1.458 0.188,0.177 10 *7 5.969,1.042 6.156,1.219 0.188,0.177 10 *5 0.938,0.177 1.125,0.354 0.188,0.177 10 *1 3.979,0.188 4.167,0.365 0.188,0.177 10 *2
*1 Air Fuel Ratio Sensor (Planar Type) *2 Oxygen Sensor (Cup Type)
*3 Platinum Electrode *4 Alumina
*5 Sensor Element (Zirconia) *6 Atmosphere
*7 Heater *8 Diffusion Resistance Layer



c.

As illustrated below, the conventional oxygen sensor is characterized by a sudden change in its output voltage at the threshold of the stoichiometric air fuel ratio (14.7:1). In contrast, the air fuel ratio sensor data is approximately proportionate to the existing air fuel ratio. The air fuel ratio sensor converts the oxygen density to current and sends it to the ECM. As a result, the detection precision of the air fuel ratio has been improved. The air fuel ratio sensor data can be viewed using the intelligent tester.

W100042
2.427,0.375 2.729,0.375 2.729,0.375 3.146,1.219 false 4.667,0.448 4.281,0.448 4.281,0.448 4.01,1.604 false 2.146,3.604 2.375,3.76 0.229,0.156 10 false 11 5.063,3.604 5.292,3.76 0.229,0.156 10 false 19 3.333,3.604 3.635,3.76 0.302,0.156 10 false 14.7 3.042,3.792 3.99,3.99 0.948,0.198 10 false Air Fuel Ratio 2.333,3.583 2.781,3.76 0.448,0.177 10 false (Rich) 5.26,3.594 5.708,3.771 0.448,0.177 10 false (Lean) 5.208,0.615 5.438,0.813 0.229,0.198 10 false (V) 1.896,0.594 2.125,0.792 0.229,0.198 10 false (V) 5.406,0.75 5.552,0.948 0.146,0.198 10 false 1 5.448,3.25 5.688,3.448 0.24,0.198 10 false 0.1 1.708,3.208 1.979,3.385 0.271,0.177 10 false 2.2 1.708,0.74 1.979,0.917 0.271,0.177 10 false 4.2 5.417,1.615 6.5,2 1.083,0.385 10 false Oxygen Sensor Output 0.635,1.563 2.031,1.906 1.396,0.344 10 false Air Fuel Ratio Sensor Output* 4.729,0.354 6.125,0.542 1.396,0.188 10 false Air Fuel Ratio Sensor 0.563,2.177 1.99,2.531 1.427,0.354 10 false (Data Displayed on the Intellegent Tester) 0.375,4.198 5.844,4.385 5.469,0.188 10 false *: This value is calculated internally in the ECM and is not an ECM terminal voltage. 1.417,0.281 2.417,0.469 1,0.188 10 false Oxygen Sensor