SYSTEM CONTROL
The air conditioning system uses the following controls.
| Control | Function | Air Conditioning Type | |
|---|---|---|---|
| Manual | Automatic | ||
| Neural Network Control | This control is capable of performing complex control by artificially simulating the information processing method of the nervous system of living organisms in order to establish a complex input/output relationship that is similar to a human brain. | - | ○ |
| Manual Control | The air conditioning amplifier assembly controls the damper positions (air inlet control servo motor, air mix control servo motor and mode control servo motor) and blower speed in accordance with the positions of the switches (temperature control switch, blower switch, mode control switch and inlet control switch). | ○ | ○ |
| Outlet Air Temperature Control | Based on the temperature set at the temperature control switch, the neural network control calculates the outlet air temperature based on the input signals from various sensors. | - | ○ |
| Left and Right Independent Control | The temperature setting for the driver and front passenger is controlled independently in order to provide a separate vehicle interior temperature for the right and left sides of the vehicle. Thus, air conditioning control that accommodates occupant preferences has been realized. | - | ○ |
| Blower Control | Controls the blower motor in accordance with the airflow volume that has been calculated by neural network control based on the input signals from various sensors. | - | ○ |
| Air Outlet Control | Automatically switches the air outlets in accordance with the outlet mode that has been calculated by neural network control based on the input signals from various sensors. | - | ○ |
| In accordance with the engine coolant temperature, outside air temperature, amount of sunlight, required blower, outlet temperature, and vehicle speed conditions, this control automatically switches the blower outlet to FOOT/DEF mode to prevent the windows from becoming fogged when the outside air temperature is low. | - | ○ | |
| Air Inlet Control | Automatically controls the air inlet control damper to achieve the calculated outlet air temperature that is required. | - | ○ |
| Compressor Control | Through the calculation of the target evaporator temperature based on various sensor signals, the air conditioning amplifier assembly optimally controls the discharge capacity by regulating the opening extent of the solenoid valve. | ○ | ○ |
| Maximum Air Conditioning Control | When the temperature control dial tuned to the MAX A/C position, the air conditioning amplifier assembly performs the following control to improve cooling efficiency:
·
Turns the compressor with pulley assembly on. ·
Activates the blower damper servo sub-assembly No. 1 (recirculation/fresh) to set the air inlet control damper to the recirculation position. |
○ | - |
| Refrigerant Shortage Detection Control | When the air conditioning is operating and the engine coolant temperature is above a specified value, the air conditioning amplifier assembly calculates the amount of refrigerant based on signals from the air conditioning pressure sensor, evaporator temperature sensor (No. 1 cooler thermistor) and outside temperature sensor (thermistor assembly). | ○ | ○ |
| Defroster Control | Defroster control logic is used to improve defroster performance. | ○ | ○ |
| Rear Window Defogger Control | When the rear defogger switch is pushed, the system is activated to keep the defogger heater on for approx. 15 minutes. However, the operating time of the rear defogger can be extended up to approx. 45 minutes when both of the following requirements are met:
·
Outside Temperature: -3°C (27°F) or below ·
Vehicle Speed: 45 km/h (28 mph) or more |
○ | ○ |
| Diagnosis | A Diagnostic Trouble Code (DTC) is stored in memory when the air conditioning amplifier assembly detects a problem with the air conditioning system. | ○ | ○ |
○: Available
- : Not available
Neural Network Control
Previously, in automatic air conditioning systems without neural network control, the air conditioning amplifier assembly determined the required outlet air temperature and blower air volume in accordance with the calculation formula that has been obtained based on information received from the sensors. However, because the senses of a person are rather complex, a given temperature is sensed differently, depending on the environment in which the person is situated. For example, a given amount of solar radiation can feel comfortably warm in a cold climate, or extremely uncomfortable in a hot climate. Therefore, as a technique for performing a higher level of control, a neural network has been adopted in the automatic air conditioning system. With this technique, the data that has been collected under varying environmental conditions is stored in the air conditioning amplifier assembly. The air conditioning amplifier assembly can then perform control in a way that provides enhanced air conditioning comfort.
The neural network control consists of neurons in the input layer, intermediate layer and output layer. The input layer neurons process the input data of the outside temperature, the amount of sunlight, and the room temperature based on the outputs of the switches and sensors, and output them to the intermediate layer neurons. Based on this data, the intermediate layer neurons adjust the strength of the links among the neurons. The sum of these is then calculated by the output layer neurons in the form of the required outlet temperature, solar correction, target airflow volume and outlet mode control volume. Accordingly, the air conditioning amplifier assembly controls the servo motors and blower motor in accordance with the control volumes that have been calculated by the neural network control.
DIAGNOSIS
The air conditioning amplifier assembly has a diagnosis function. It stores a record of any air conditioning system failures in its memory in the form of Diagnostic Trouble Codes (DTCs). For details, refer to the Repair Manual.