RM19V0EQ
_V1
General
_014571
SPECIFICATIONS
_0073862
2AR-FE COOLING
F
SPECIFICATIONS 2AR-FE COOLING SERVICE DATA
THERMOSTAT
| Condition
|
Specified Condition
|
| Standard valve opening temperature
|
80 to 84°C (176 to 183°F)
|
| Standard valve lift
|
10 mm (0.394 in.) or more at 95°C (203°F)
|
COOLING FAN MOTOR
| Item
|
Code Mark
|
Condition
|
Specified Condition
|
| Cooling fan motor
|
S
|
Battery voltage applied at 20°C (68°F)
|
7.4 to 11.4 A
|
| M
|
7.7 to 11.7 A
|
| No. 2 cooling fan motor
|
S
|
Battery voltage applied at 20°C (68°F)
|
7.4 to 11.4 A
|
| M
|
7.7 to 11.7 A
|
COOLING FAN RELAY
| Tester Connection
|
Condition
|
Specified Condition
|
| 3 - 4
|
Battery voltage not applied between terminals 1 and 2
|
Below 1 Ω
|
| 3 - 5
|
Battery voltage not applied between terminals 1 and 2
|
10 kΩ or higher
|
| 3 - 4
|
Battery voltage applied between terminals 1 and 2
|
10 kΩ or higher
|
| 3 - 5
|
Battery voltage applied between terminals 1 and 2
|
Below 1 Ω
|
RADIATOR
| Item
|
Condition
|
Specified Condition
|
| Radiator cap
|
Standard value (for brand-new cap)
|
93.3 to 122.7 kPa (0.95 to 1.25 kgf/cm2, 13.5 to 17.8 psi)
|
| Minimum standard value (for used cap)
|
78.5 kPa (0.8 kgf/cm2, 11.4 psi)
|
COOLANT
| Code Mark
|
Capacity
|
Classification
|
| Code Mark "A" and "B"
|
7.9 liters (8.3 US qts, 7.0 lmp. qts)
|
Use only "TOYOTA Super Long Life Coolant", or similar high qualityethylene glycol based non-silicate, non-amine, non-nitrite, and nonboratecoolant with long-life hybrid organic acid technology (coolantwith long-life hybrid organic acid technology is a combination of lowphosphates and organic acids).
|
| Code Mark "D" and "U"
|
7.5 liters (7.9 US qts, 6.6 lmp. qts)
|