Home › Engine / Hybrid System › 2AR-FE ENGINE CONTROL › INTEGRATION RELAY
RM19V0EQ _51 Engine / Hybrid System _014573 2AR-FE ENGINE CONTROL _0073924 INTEGRATION RELAY G

2AR-FE ENGINE CONTROL  INTEGRATION RELAY  INSPECTION  


PROCEDURE

Hide 82641 1.INSPECT NO. 1 INTEGRATION RELAY

A255144
0.818,1.793 1.049,1.996 0.231,0.203 10 1A 0.874,1.623 1.033,1.826 0.158,0.203 10 8 6.167,0.288 6.43,0.492 0.263,0.203 10 1C 6.209,0.109 6.367,0.312 0.158,0.203 10 4 6.209,0.444 6.367,0.648 0.158,0.203 10 3 6.209,0.907 6.367,1.111 0.158,0.203 10 9 6.181,1.25 6.361,1.454 0.18,0.203 10 10 6.181,1.808 6.379,2.011 0.198,0.203 10 1B 6.167,2.136 6.397,2.34 0.231,0.203 10 1C 6.209,1.651 6.312,1.854 0.103,0.203 10 1 6.209,1.982 6.312,2.185 0.103,0.203 10 7 6.209,2.895 6.312,3.098 0.103,0.203 10 1 6.151,3.074 6.366,3.277 0.215,0.203 10 1D 6.152,4.401 6.366,4.605 0.215,0.203 10 1C 6.209,4.237 6.367,4.441 0.158,0.203 10 6 6.152,4.725 6.366,4.928 0.215,0.203 10 1E 6.209,4.563 6.367,4.766 0.158,0.203 10 1 6.166,5.896 6.38,6.099 0.215,0.203 10 1D 6.209,5.725 6.367,5.929 0.158,0.203 10 3 6.152,6.228 6.366,6.431 0.215,0.203 10 1C 6.209,6.077 6.367,6.281 0.158,0.203 10 8 6.152,6.589 6.366,6.793 0.215,0.203 10 1E 6.209,6.426 6.367,6.629 0.158,0.203 10 2 6.152,6.907 6.366,7.11 0.215,0.203 10 1C 6.152,7.234 6.366,7.438 0.215,0.203 10 1C 6.152,7.575 6.366,7.733 0.215,0.158 10 1C 6.225,6.758 6.383,6.961 0.158,0.203 10 5 6.209,7.069 6.367,7.272 0.158,0.203 10 2 6.209,7.404 6.367,7.608 0.158,0.203 10 1 4.037,2.397 4.709,2.66 0.673,0.263 10 EFI MAIN 3.966,3.662 4.733,3.925 0.767,0.263 10 EFI MAIN2 4.122,5.007 4.593,5.27 0.471,0.263 10 C/OPN 4.225,6.422 4.526,6.685 0.301,0.263 10 IG2 2.437,1.979 3.109,2.242 0.673,0.263 10 EFI NO. 3 3.338,1.231 4.011,1.494 0.673,0.263 10 EFI NO. 2 1.741,6.025 2.085,6.288 0.344,0.263 10 IGN 1.755,6.402 2.021,6.665 0.266,0.263 10 INJ 1.441,7.038 2.447,7.301 1.006,0.263 10 ECU-IG2 NO.3 0.874,2.884 1.033,3.087 0.158,0.203 10 7 0.874,3.239 1.033,3.442 0.158,0.203 10 6 0.874,5.705 1.033,5.908 0.158,0.203 10 1 0.874,6.097 1.033,6.3 0.158,0.203 10 3 0.095,0.054 0.308,0.257 0.213,0.203 10 *1 0.828,3.071 1.059,3.274 0.231,0.203 10 1A 0.828,3.38 1.059,3.584 0.231,0.203 10 1A 0.832,5.874 1.063,6.077 0.231,0.203 10 1A 0.84,6.249 1.071,6.452 0.231,0.203 10 1A 6.171,0.616 6.434,0.819 0.263,0.203 10 1C 6.172,1.088 6.435,1.292 0.263,0.203 10 1C 6.169,1.414 6.432,1.618 0.263,0.203 10 1C
*1 No. 1 Integration Relay - -


a.

EFI MAIN relay:

i.
A255141
1.052,0.5 1.542,0.792 0.49,0.292 0.74,2.229 1.229,2.521 0.49,0.292 1.313,2.229 1.802,2.521 0.49,0.292 1.906,2.229 2.396,2.521 0.49,0.292 2.438,2.229 2.927,2.521 0.49,0.292 1.198,0.552 1.583,0.76 0.385,0.208 10 false 1A 0.885,2.281 1.208,2.49 0.323,0.208 10 false 1B 1.448,2.281 1.74,2.458 0.292,0.177 10 false 1C 2.031,2.281 2.344,2.458 0.313,0.177 10 false 1D 2.583,2.281 2.875,2.448 0.292,0.167 10 false 1E 0.104,0.094 0.406,0.333 0.302,0.24 10 false *1
*1 No. 1 Integration Relay


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
No. 1 integration relay 1B-1 - No. 1 integration relay 1A-8 Battery voltage is not applied between terminals 1C-7 and 1E-2 10 kΩ or higher
No. 1 integration relay 1B-1 - No. 1 integration relay 1A-8 Battery voltage is applied between terminals 1C-7 and 1E-2 Below 1 Ω
No. 1 integration relay 1B-1 - No. 1 integration relay 1C-3
No. 1 integration relay 1B-1 - No. 1 integration relay 1C-4
No. 1 integration relay 1B-1 - No. 1 integration relay 1C-9
No. 1 integration relay 1B-1 - No. 1 integration relay 1C-10


If the resistance is not as specified, replace the No. 1 integration relay.



b.

EFI MAIN2 relay:

i.
A255141
1.052,0.5 1.542,0.792 0.49,0.292 0.74,2.229 1.229,2.521 0.49,0.292 1.313,2.229 1.802,2.521 0.49,0.292 1.906,2.229 2.396,2.521 0.49,0.292 2.438,2.229 2.927,2.521 0.49,0.292 1.198,0.552 1.583,0.76 0.385,0.208 10 false 1A 0.885,2.281 1.208,2.49 0.323,0.208 10 false 1B 1.448,2.281 1.74,2.458 0.292,0.177 10 false 1C 2.031,2.281 2.344,2.458 0.313,0.177 10 false 1D 2.583,2.281 2.875,2.448 0.292,0.167 10 false 1E 0.104,0.094 0.406,0.333 0.302,0.24 10 false *1
*1 No. 1 Integration Relay


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
No. 1 integration relay 1A-6 - No. 1 integration relay 1D-1 Battery voltage is not applied between terminals 1A-8 and 1E-2 10 kΩ or higher
No. 1 integration relay 1A-6 - No. 1 integration relay 1D-1 Battery voltage is applied between terminals 1A-8 and 1E-2 Below 1 Ω
No. 1 integration relay 1A-7 - No. 1 integration relay 1D-1


If the resistance is not as specified, replace the No. 1 integration relay.



c.

IG2 relay:

i.
A255141
1.052,0.5 1.542,0.792 0.49,0.292 0.74,2.229 1.229,2.521 0.49,0.292 1.313,2.229 1.802,2.521 0.49,0.292 1.906,2.229 2.396,2.521 0.49,0.292 2.438,2.229 2.927,2.521 0.49,0.292 1.198,0.552 1.583,0.76 0.385,0.208 10 false 1A 0.885,2.281 1.208,2.49 0.323,0.208 10 false 1B 1.448,2.281 1.74,2.458 0.292,0.177 10 false 1C 2.031,2.281 2.344,2.458 0.313,0.177 10 false 1D 2.583,2.281 2.875,2.448 0.292,0.167 10 false 1E 0.104,0.094 0.406,0.333 0.302,0.24 10 false *1
*1 No. 1 Integration Relay


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
No. 1 integration relay 1A-1 - No. 1 integration relay 1D-3 Battery voltage is not applied between terminals 1C-8 and 1E-2 10 kΩ or higher
No. 1 integration relay 1A-1 - No. 1 integration relay 1D-3 Battery voltage is applied between terminals 1C-8 and 1E-2 Below 1 Ω
No. 1 integration relay 1A-3 - No. 1 integration relay 1D-3
No. 1 integration relay 1C-1 - No. 1 integration relay 1D-3
No. 1 integration relay 1C-2 - No. 1 integration relay 1D-3
No. 1 integration relay 1C-5 - No. 1 integration relay 1D-3


If the resistance is not as specified, replace the No. 1 integration relay.



d.

C/OPN relay:

i.
A255141
1.052,0.5 1.542,0.792 0.49,0.292 0.74,2.229 1.229,2.521 0.49,0.292 1.313,2.229 1.802,2.521 0.49,0.292 1.906,2.229 2.396,2.521 0.49,0.292 2.438,2.229 2.927,2.521 0.49,0.292 1.198,0.552 1.583,0.76 0.385,0.208 10 false 1A 0.885,2.281 1.208,2.49 0.323,0.208 10 false 1B 1.448,2.281 1.74,2.458 0.292,0.177 10 false 1C 2.031,2.281 2.344,2.458 0.313,0.177 10 false 1D 2.583,2.281 2.875,2.448 0.292,0.167 10 false 1E 0.104,0.094 0.406,0.333 0.302,0.24 10 false *1
*1 No. 1 Integration Relay


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
No. 1 integration relay 1A-6 - No. 1 integration relay 1C-6 Battery voltage is not applied between terminals 1A-1 and 1E-1 10 kΩ or higher
No. 1 integration relay 1A-6 - No. 1 integration relay 1C-6 Battery voltage is applied between terminals 1A-1 and 1E-1 Below 1 Ω
No. 1 integration relay 1A-7 - No. 1 integration relay 1C-6


If the resistance is not as specified, replace the No. 1 integration relay.