Home › Engine / Hybrid System › 2AR-FE INTAKE / EXHAUST › INTAKE MANIFOLD
RM19V0EQ _51 Engine / Hybrid System _014577 2AR-FE INTAKE / EXHAUST _0073948 INTAKE MANIFOLD G

2AR-FE INTAKE / EXHAUST  INTAKE MANIFOLD  INSPECTION  


PROCEDURE

Hide 1.INSPECT INTAKE AIR CONTROL VALVE (for ACIS)

a.

Inspect the diaphragm.

i.
A298534

Using a vacuum pump, apply a vacuum of 60 kPa (450 mmHg, 17.7 in.Hg) or higher to the diaphragm chamber. Wait for 1 minute and check that the needle of the vacuum pump does not lower.

If the result is not as specified, replace the intake manifold.



b.

After applying vacuum in the step above, check that the actuator rod operates.


Hide 2.INSPECT VACUUM TANK AND NO. 1 CHECK VALVE

a.
A197175

Disconnect the vacuum hose from the No. 1 check valve.


b.

Using a vacuum pump, apply vacuum to the No. 1 check valve. Wait for 1 minute and check that the needle of the vacuum pump does not lower.

If the result is not as specified, replace the No. 1 check valve.


c.

Connect the vacuum hose to the No. 1 check valve.


d.
A196058

Using a vacuum pump, apply a vacuum of 60 kPa (450 mmHg, 17.7 in.Hg) or higher to the vacuum tank. Wait for 1 minute and check that the needle of the vacuum pump does not lower.

If the result is not as specified, replace the intake manifold.