17650
1.INSPECT VACUUM SWITCHING VALVE ASSEMBLY (for ACIS)
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 20°C (68°F) | 37 to 44 Ω |
| 1 - Valve body | Always | 10 kΩ or higher |
| 2 - Valve body |
If the result is not as specified, replace the vacuum switching valve.
| *1 | Filter |
| *a | Port E |
| *b | Port F |
Using a vacuum pump, check that air flows through the vacuum switching valve as specified.
| Measurement Condition | Specified Condition |
|---|---|
| Battery voltage applied between terminals 1 and 2 and vacuum applied to port F. | Air is sucked into port E. |
| Battery voltage not applied between terminals 1 and 2 and vacuum applied to port E. | Air is sucked into filter. |
If the result is not as specified, replace the vacuum switching valve.