Home › Drivetrain › U760E AUTOMATIC TRANSMISSION / TRANSAXLE › VALVE BODY ASSEMBLY
RM19V0EQ _52 Drivetrain _014582 U760E AUTOMATIC TRANSMISSION / TRANSAXLE _0073977 VALVE BODY ASSEMBLY G

U760E AUTOMATIC TRANSMISSION / TRANSAXLE  VALVE BODY ASSEMBLY  INSPECTION  


PROCEDURE

Hide 35240 1.INSPECT SHIFT SOLENOID VALVE SL

a.
C188295
0.156,0.104 0.552,0.427 0.396,0.323 10 false *a
*a Component without harness connected
(Shift Solenoid Valve SL)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Solenoid Connector - Solenoid Body 20°C (68°F) 11 to 15 Ω


If the result is not as specified, replace the shift solenoid valve SL.



b.

Connect a battery positive (+) lead to the terminal of the solenoid valve connector, and a negative (-) lead to the solenoid body. Then check that the valve moves and makes an operating sound.

NOTICE:

When using battery voltage during the inspection, do not bring the positive (+) and negative (-) tester probes too close to each other as a short circuit may occur.


OK:

Valve moves and makes an operating sound.


If the result is not as specified, replace the shift solenoid valve SL.



Hide 35290 2.INSPECT SHIFT SOLENOID VALVE SLT

a.
C201747
1.51,0.802 0.656,0.573 false 1.781,0.792 2.479,0.552 false 1.51,3.052 0.656,2.823 false 1.781,3.042 2.479,2.802 false 0.49,0.479 0.667,0.677 0.177,0.198 10 false 1 2.531,0.479 2.708,0.677 0.177,0.198 10 false 2 1.167,4.146 1.375,4.354 0.208,0.208 10 false (-) 1.917,4.146 2.146,4.344 0.229,0.198 10 false (+) 0.49,2.729 0.667,2.927 0.177,0.198 10 false 1 2.531,2.729 2.708,2.927 0.177,0.198 10 false 2 0.135,0.104 0.531,0.385 0.396,0.281 10 false *a
*a Component without harness connected
(Shift Solenoid Valve SLT)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 5.0 to 5.6 Ω


If the result is not as specified, replace the shift solenoid valve SLT.


b.

Connect a battery positive (+) lead with a 21 W bulb to terminal 2 and a negative (-) lead to terminal 1 of the solenoid valve connector. Then check that the valve moves and makes an operating sound.

NOTICE:

When using battery voltage during the inspection, do not bring the positive (+) and negative (-) tester probes too close to each other as a short circuit may occur.


OK:

Valve moves and makes an operating sound.


If the result is not as specified, replace the shift solenoid valve SLT.


Hide 35280 3.INSPECT SHIFT SOLENOID VALVE SLU

HINT:

Refer to Inspect Shift Solenoid Valve SLT.


Hide 35210 4.INSPECT SHIFT SOLENOID VALVE SL1

HINT:

Refer to Inspect Shift Solenoid Valve SLT.


Hide 35220 5.INSPECT SHIFT SOLENOID VALVE SL2

HINT:

Refer to Inspect Shift Solenoid Valve SLT.


Hide 6.INSPECT SHIFT SOLENOID VALVE SL3

HINT:

Refer to Inspect Shift Solenoid Valve SLT.


Hide 7.INSPECT SHIFT SOLENOID VALVE SL4

HINT:

Refer to Inspect Shift Solenoid Valve SLT.