2AR-FE BATTERY / CHARGING  GENERATOR  INSPECTION  


PROCEDURE

Hide 27415 1.INSPECT GENERATOR PULLEY WITH CLUTCH

a.
A192786C01
2.375,0.917 2.542,1.094 0.167,0.177 10 *b 0.917,0.917 1.094,1.094 0.177,0.177 10 *a
*a Free
*b Lock


Hold the center of the pulley, and confirm that the outer ring turns counterclockwise and does not turn clockwise.

If the result is not as specified, replace the generator pulley with clutch.

If the result is not as specified, replace the generator pulley with clutch.


Hide 27310B 2.INSPECT GENERATOR DRIVE END FRAME BEARING

a.
A192785

Check that the bearing is not rough or worn and that it rotates smoothly.

OK:

The bearing rotates smoothly.


If the bearing does not rotate smoothly, replace the bearing.


Hide 27370 3.INSPECT GENERATOR BRUSH HOLDER ASSEMBLY

a.
A128079C12
0.627,0.709 0.823,0.866 0.197,0.157 10 *a
*a Length


Using a vernier caliper, measure the brush length.

Standard length:

9.5 to 11.5 mm (0.374 to 0.453 in.)


Minimum length:

4.5 mm (0.177 in.)


If the brush length is less than the minimum, replace the generator brush holder assembly.


Hide 27330 4.INSPECT GENERATOR ROTOR ASSEMBLY

a.
A192784

Check that the generator rotor bearing is not rough or worn.

If the result is not as specified, replace the generator rotor assembly.


b.
A097476
1.938,0.417 1.656,0.927 false 1.938,0.417 1.802,0.969 false 1.979,0.302 2.156,0.479 0.177,0.177 10 *1 2.594,0.625 2.771,0.802 0.177,0.177 10 *2
*1 Slip Ring
*2 Ohmmeter


Check the rotor for an open circuit.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Slip ring - Slip ring Approx. 20°C (68°F) 2.3 to 2.7 Ω


If the result is not as specified, replace the generator rotor assembly.



c.
A097477
1.792,0.979 2.021,0.104 2.021,0.104 2.104,0.104 false 0.896,0.906 1.063,1.573 false 0.969,1.573 1.177,1.74 0.208,0.167 10 *3 2.167,0.021 2.313,0.198 0.146,0.177 10 *1 2.625,0.615 2.771,0.792 0.146,0.177 10 *2
*1 Slip Ring
*2 Ohmmeter
*3 Rotor


Check if the rotor is grounded.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Slip ring - Rotor Always 10 kΩ or higher


If the result is not as specified, replace the generator rotor assembly.



d.

Check the slip ring diameter.

i.
A097470C04
0.646,0.094 0.813,0.25 0.167,0.156 10 *a
*a Diameter


Using a vernier caliper, measure the diameter of each slip ring.

Standard diameter:

14.2 to 14.4 mm (0.559 to 0.567 in.)


Minimum diameter:

14 mm (0.551 in.)


If the diameter is less than the minimum, replace the generator rotor assembly.