The network gateway ECU will store this DTC when no signals can be received from the ECUs that have been memorized as those that are connected to sub bus 2.
When the network gateway ECU receives a response signal from the ECUs connected to sub bus 2, the network gateway ECU recognizes and memorizes that the ECU is connected to sub bus 2. Based on this memorized data, the network gateway ECU monitors for malfunctions in the ECUs connected to sub bus 2 when communicating with those ECUs. If the network gateway ECU cannot receive response signals from the ECUs that have been memorized as those connected to sub bus 2, the network gateway ECU determines that a malfunction exists.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Note |
|---|---|---|---|---|
| U1002 | Lost Communication with Gateway Module (Network Gateway ECU) | Network gateway ECU cannot receive signals from all ECUs that have been memorized as those connected to sub bus 2. | ·
Open or short in sub bus 2 main line or connector ·
Open or short in sub bus 2 branch line or connector ·
Network gateway ECU ·
Blind spot monitor sensor LH ·
Blind spot monitor sensor RH ·
Open or short in CAN No. 5 junction connector ·
Open or short in CAN No. 6 junction connector ·
Open or short in CAN No. 7 junction connector |
The network gateway ECU stores DTCs when it detects a communication stop or network communication error for ECUs connected to sub bus 2. |
This diagnosis procedure is for when DTC U1002 is output by the network gateway ECU (Intelligent tester display: Gateway).
Before measuring the resistance of the CAN bus, turn the ignition switch off and leave the vehicle for 1 minute or more without operating the key, switches or opening or closing the doors. After that, disconnect the cable from the negative (-) battery terminal and leave the vehicle for 1 minute or more before measuring the resistance.
After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) battery terminal notice before proceeding with work.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION
Because the order of diagnosis is important to allow correct diagnosis, make sure to begin troubleshooting using How to Proceed with Troubleshooting when CAN communication system related DTCs are output.
Click herePower Source / Network>NETWORKING>CAN COMMUNICATION SYSTEM>HOW TO PROCEED WITH TROUBLESHOOTING
After performing repairs, perform the DTC check procedure and confirm that the DTCs are not output again.
DTC check procedure: Turn the ignition switch to ON, turn the blind spot monitor system on using the blind spot monitor main switch (ON/OFF switch), wait at least 22 seconds, and then drive the vehicle at a speed of 5 km/h (3 mph) or more.
After the repair, perform Communication Bus Check and check that all the ECUs and sensors connected to the CAN communication system are displayed.
Click herePower Source / Network>NETWORKING>CAN COMMUNICATION SYSTEM>DIAGNOSIS SYSTEM
Operating the ignition switch, any other switches or a door triggers related ECU and sensor communication on the CAN. This communication will cause the resistance value to change.
Even after DTCs are cleared, if a DTC is stored again after driving the vehicle for a while, the malfunction may be occurring due to vibration of the vehicle. In such a case, wiggling the ECUs or wire harness while performing the inspection below may help determine the cause of the malfunction.
Disconnect the cable from the negative (-) battery terminal.
| *a | Component with harness connected
(Network Gateway ECU) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition | Result |
|---|---|---|---|
| I160-13 (CA2H) - I160-12 (CA2L) | Cable disconnected from negative (-) battery terminal | 54 to 69 Ω | Below 54 Ω: Short circuit between bus lines |
| 70 Ω or higher: Open circuit in a main bus line | |||
| I160-13 (CA2H) - I160-4 (GND) | Cable disconnected from negative (-) battery terminal | 200 Ω or higher | Below 200 Ω: CANH ground short |
| I160-12 (CA2L) - I160-4 (GND) | Cable disconnected from negative (-) battery terminal | 200 Ω or higher | Below 200 Ω: CANL ground short |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition | Result |
|---|---|---|---|
| I160-13 (CA2H) - I160-2 (BATT) | Cable disconnected from negative (-) battery terminal | 6 kΩ or higher | Below 6 kΩ: CANH +B short |
| I160-12 (CA2L) - I160-2 (BATT) | Cable disconnected from negative (-) battery terminal | 6 kΩ or higher | Below 6 kΩ: CANL +B short |
| Result | Proceed to |
|---|---|
| OK | A |
| Open circuit in CAN main bus line | B |
| Short circuit between bus lines | C |
·
Ground short ·
+B short |
D |
A
B
C
D
Reconnect the cable to the negative (-) battery terminal.
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the intelligent tester on.
Clear the DTCs.
Turn the ignition switch off.
Turn the ignition switch to ON and recheck for DTCs.
| Result | Proceed to |
|---|---|
| U1002 is output from network gateway ECU
(Intelligent tester display: Gateway) |
A |
| Other DTC is output | B |
A
B
| *a | Front view of wire harness connector
(to Network Gateway ECU) |
Disconnect the network gateway ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| I160-13 (CA2H) - I160-12 (CA2L) | Cable disconnected from negative (-) battery terminal | 108 to 132 Ω |
| Result |
|---|
| OK |
| NG |
OK
NG
Reconnect the network gateway ECU connector.
Disconnect the wire harness connector from the CAN No. 5 junction connector.
| *a | Front view of wire harness connector
(to CAN No. 5 Junction Connector) |
| *b | to CAN No. 6 Junction Connector |
| *c | to Network Gateway ECU |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| O31-10 (CANH) - O31-21 (CANL) | Cable disconnected from negative (-) battery terminal | 108 to 132 Ω |
| O31-11 (CANH) - O31-22 (CANL) | Cable disconnected from negative (-) battery terminal | 108 to 132 Ω |
| Result | Proceed to |
|---|---|
| OK | A |
| NG (to Network Gateway ECU main bus line) | B |
| NG (to CAN No. 6 junction connector main bus line) | C |
A
B
C
Reconnect the wire harness connector to the CAN No. 5 junction connector.
Disconnect the wire harness connector from the CAN No. 6 junction connector.
| *a | Front view of wire harness connector
(to CAN No. 6 Junction Connector) |
| *b | to CAN No. 7 Junction Connector |
| *c | to CAN No. 5 Junction Connector |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| T17-9 (CANH) - T17-20 (CANL) | Cable disconnected from negative (-) battery terminal | 108 to 132 Ω |
| T17-11 (CANH) - T17-22 (CANL) | Cable disconnected from negative (-) battery terminal | 108 to 132 Ω |
| Result | Proceed to |
|---|---|
| OK | A |
| NG (to CAN No. 5 junction connector main bus line) | B |
| NG (to CAN No. 7 junction connector main bus line) | C |
A
B
C
Reconnect the wire harness connector to the CAN No. 6 junction connector.
Disconnect the instrument panel wire from the CAN No. 7 junction connector.
| *a | Rear view of wire harness connector
(to CAN No. 7 Junction Connector) |
| *b | to CAN No. 6 Junction Connector |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| T18-3 (CANH) - T18-2 (CANL) | Cable disconnected from negative (-) battery terminal | 108 to 132 Ω |
| Result |
|---|
| OK |
| NG |
OK
NG
| *a | Front view of wire harness connector
(to Network Gateway ECU) |
Disconnect the network gateway ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| I160-13 (CA2H) - I160-12 (CA2L) | Cable disconnected from negative (-) battery terminal | 108 to 132 Ω |
| Result |
|---|
| OK |
| NG |
OK
NG
Reconnect the network gateway ECU connector.
Disconnect the wire harness connector from the CAN No. 5 junction connector.
| *a | Front view of wire harness connector
(to CAN No. 5 Junction Connector) |
| *b | to Blind Spot Monitor Sensor RH |
| *c | to CAN No. 6 Junction Connector |
| *d | to Network Gateway ECU |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| O31-9 (CANH) - O31-20 (CANL) | Cable disconnected from negative (-) battery terminal | 200 Ω or higher |
| O31-10 (CANH) - O31-21 (CANL) | Cable disconnected from negative (-) battery terminal | 108 to 132 Ω |
| O31-11 (CANH) - O31-22 (CANL) | Cable disconnected from negative (-) battery terminal | 108 to 132 Ω |
| Result | Proceed to |
|---|---|
| OK | A |
| NG (to Network Gateway ECU main bus line) | B |
| NG (to CAN No. 6 junction connector main bus line) | C |
| NG (to Blind spot monitor sensor RH) | D |
A
B
C
D
Reconnect the wire harness connector to the CAN No. 5 junction connector.
Disconnect the wire harness connector from the CAN No. 6 junction connector.
| *a | Front view of wire harness connector
(to CAN No. 6 Junction Connector) |
| *b | to CAN No. 7 Junction Connector |
| *c | to Blind Spot Monitor Sensor LH |
| *d | to CAN No. 5 Junction Connector |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| T17-9 (CANH) - T17-20 (CANL) | Cable disconnected from negative (-) battery terminal | 108 to 132 Ω |
| T17-10 (CANH) - T17-21 (CANL) | Cable disconnected from negative (-) battery terminal | 200 Ω or higher |
| T17-11 (CANH) - T17-22 (CANL) | Cable disconnected from negative (-) battery terminal | 108 to 132 Ω |
| Result | Proceed to |
|---|---|
| OK | A |
| NG (to CAN No. 5 junction connector main bus line) | B |
| NG (to CAN No. 7 junction connector main bus line) | C |
| NG (to Blind spot monitor sensor LH) | D |
A
B
C
D
Reconnect the wire harness connector to the CAN No. 6 junction connector.
Disconnect the wire harness connector from the CAN No. 7 junction connector.
| *a | Rear view of wire harness connector
(to CAN No. 7 Junction Connector) |
| *b | to CAN No. 6 Junction Connector |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| T18-3 (CANH) - T18-2 (CANL) | Cable disconnected from negative (-) battery terminal | 108 to 132 Ω |
| Result |
|---|
| OK |
| NG |
OK
NG
Reconnect all wire harness connectors (CAN No. 5 junction connector and CAN No. 6 junction connector).
Disconnect the connector that includes terminals CANH and CANL from the ECU (or sensor) to which the short-circuited branch line is connected.
Click herePower Source / Network>NETWORKING>CAN COMMUNICATION SYSTEM>TERMINALS OF ECU
| *a | Component with harness connected
(Network Gateway ECU) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| I160-13 (CA2H) - I160-12 (CA2L) | Cable disconnected from negative (-) battery terminal | 54 to 69 Ω |
If the resistance becomes normal (between 54 and 69 Ω) when the connector is disconnected from the ECU (or sensor), there may be a short in the ECU (or sensor).
If the resistance does not become normal (between 54 and 69 Ω) when the connector is disconnected from the ECU (or sensor), repair or replace the short-circuited branch line or connector.
| Result |
|---|
| OK |
| NG |
OK
NG
Disconnect the wire harness connector from the CAN No. 5 junction connector.
Measure the resistance according to the value(s) in the table below.
| *1 | DLC3 | - | - |
| *a | Front view of wire harness connector
(to CAN No. 5 Junction Connector) |
*b | to Blind Spot Monitor Sensor RH |
| *c | to CAN No. 6 Junction Connector | *d | to Network Gateway ECU |
| Tester Connection | Condition | Specified Condition | Purpose | Connected to |
|---|---|---|---|---|
| O31-9 (CANH) - I39-4 (CG) | Cable disconnected from negative (-) battery terminal | 200 Ω or higher | Inspection for CANH ground short | Blind spot monitor sensor RH |
| O31-20 (CANL) - I39-4 (CG) | Cable disconnected from negative (-) battery terminal | 200 Ω or higher | Inspection for CANL ground short | |
| O31-10 (CANH) - I39-4 (CG) | Cable disconnected from negative (-) battery terminal | 200 Ω or higher | Inspection for CANH ground short | CAN No. 6 junction connector |
| O31-21 (CANL) - I39-4 (CG) | Cable disconnected from negative (-) battery terminal | 200 Ω or higher | Inspection for CANL ground short | |
| O31-11 (CANH) - I39-4 (CG) | Cable disconnected from negative (-) battery terminal | 200 Ω or higher | Inspection for CANH ground short | Network gateway ECU |
| O31-22 (CANL) - I39-4 (CG) | Cable disconnected from negative (-) battery terminal | 200 Ω or higher | Inspection for CANL ground short | |
| O31-9 (CANH) - I39-16 (BAT) | Cable disconnected from negative (-) battery terminal | 6 kΩ or higher | Inspection for CANH +B short | Blind spot monitor sensor RH |
| O31-20 (CANL) - I39-16 (BAT) | Cable disconnected from negative (-) battery terminal | 6 kΩ or higher | Inspection for CANL +B short | |
| O31-10 (CANH) - I39-16 (BAT) | Cable disconnected from negative (-) battery terminal | 6 kΩ or higher | Inspection for CANH +B short | CAN No. 6 junction connector |
| O31-21 (CANL) - I39-16 (BAT) | Cable disconnected from negative (-) battery terminal | 6 kΩ or higher | Inspection for CANL +B short | |
| O31-11 (CANH) - I39-16 (BAT) | Cable disconnected from negative (-) battery terminal | 6 kΩ or higher | Inspection for CANH +B short | Network gateway ECU |
| O31-22 (CANL) - I39-16 (BAT) | Cable disconnected from negative (-) battery terminal | 6 kΩ or higher | Inspection for CANL +B short |
| Result | Proceed to |
|---|---|
| OK | A |
| NG (to Network Gateway ECU main bus line) | B |
| NG (to CAN No. 6 junction connector main bus line) | C |
| NG (to Blind spot monitor sensor RH) | D |
It is only necessary to perform the inspection in the above table for the result (short circuit) that was obtained in the Check Sub Bus 2 inspection.
Find the necessary inspection from the Purpose column that matches the result in the Result column from the Check Sub Bus 2 inspection.
A
B
C
D
Disconnect the network gateway ECU connector.
| *a | Front view of wire harness connector
(to Network Gateway ECU) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition | Purpose |
|---|---|---|---|
| I160-13 (CA2H) - I160-4 (GND) | Cable disconnected from negative (-) battery terminal | 200 Ω or higher | Below 200 Ω: CANH ground short |
| I160-12 (CA2L) - I160-4 (GND) | Cable disconnected from negative (-) battery terminal | 200 Ω or higher | Below 200 Ω: CANL ground short |
| I160-13 (CA2H) - I160-2 (BATT) | Cable disconnected from negative (-) battery terminal | 6 kΩ or higher | Below 6 kΩ: CANH +B short |
| I160-12 (CA2L) - I160-2 (BATT) | Cable disconnected from negative (-) battery terminal | 6 kΩ or higher | Below 6 kΩ: CANL +B short |
| Result |
|---|
| OK |
| NG |
It is only necessary to perform the inspection in the above table for the result (short circuit) that was obtained in the Check Sub Bus 2 inspection.
Find the necessary inspection from the Purpose column that matches the result in the Result column from the Check Sub Bus 2 inspection.
OK
NG
Disconnect the wire harness connector from the CAN No. 6 junction connector.
Measure the resistance according to the value(s) in the table below.
| *1 | DLC3 | - | - |
| *a | Front view of wire harness connector
(to CAN No. 6 Junction Connector) |
*b | to CAN No. 7 Junction Connector |
| *c | to Blind Spot Monitor Sensor LH | *d | to CAN No. 5 Junction Connector |
| Tester Connection | Condition | Specified Condition | Purpose | Connected to |
|---|---|---|---|---|
| T17-9 (CANH) - I39-4 (CG) | Cable disconnected from negative (-) battery terminal | 200 Ω or higher | Inspection for CANH ground short | CAN No. 7 junction connector |
| T17-20 (CANL) - I39-4 (CG) | Cable disconnected from negative (-) battery terminal | 200 Ω or higher | Inspection for CANL ground short | |
| T17-10 (CANH) - I39-4 (CG) | Cable disconnected from negative (-) battery terminal | 200 Ω or higher | Inspection for CANH ground short | Blind spot monitor sensor LH |
| T17-21 (CANL) - I39-4 (CG) | Cable disconnected from negative (-) battery terminal | 200 Ω or higher | Inspection for CANL ground short | |
| T17-11 (CANH) - I39-4 (CG) | Cable disconnected from negative (-) battery terminal | 200 Ω or higher | Inspection for CANH ground short | CAN No. 5 junction connector |
| T17-22 (CANL) - I39-4 (CG) | Cable disconnected from negative (-) battery terminal | 200 Ω or higher | Inspection for CANL ground short | |
| T17-9 (CANH) - I39-16 (BAT) | Cable disconnected from negative (-) battery terminal | 6 kΩ or higher | Inspection for CANH +B short | CAN No. 7 junction connector |
| T17-20 (CANL) - I39-16 (BAT) | Cable disconnected from negative (-) battery terminal | 6 kΩ or higher | Inspection for CANL +B short | |
| T17-10 (CANH) - I39-16 (BAT) | Cable disconnected from negative (-) battery terminal | 6 kΩ or higher | Inspection for CANH +B short | Blind spot monitor sensor LH |
| T17-21 (CANL) - I39-16 (BAT) | Cable disconnected from negative (-) battery terminal | 6 kΩ or higher | Inspection for CANL +B short | |
| T17-11 (CANH) - I39-16 (BAT) | Cable disconnected from negative (-) battery terminal | 6 kΩ or higher | Inspection for CANH +B short | CAN No. 5 junction connector |
| T17-22 (CANL) - I39-16 (BAT) | Cable disconnected from negative (-) battery terminal | 6 kΩ or higher | Inspection for CANL +B short |
| Result | Proceed to |
|---|---|
| OK | A |
| NG (to CAN No. 5 junction connector main bus line) | B |
| NG (to CAN No. 7 junction connector main bus line) | C |
| NG (to Blind spot monitor sensor LH) | D |
It is only necessary to perform the inspection in the above table for the result (short circuit) that was obtained in the Check Sub Bus 2 inspection.
Find the necessary inspection from the Purpose column that matches the result in the Result column from the Check Sub Bus 2 inspection.
A
B
C
D
Disconnect the wire harness connector from the CAN No. 7 junction connector.
| *1 | DLC3 |
| *a | Front view of wire harness connector
(to CAN No. 7 Junction Connector) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition | Purpose |
|---|---|---|---|
| T18-3 (CANH) - I39-4 (CG) | Cable disconnected from negative (-) battery terminal | 200 Ω or higher | Below 200 Ω: CANH ground short |
| T18-2 (CANL) - I39-4 (CG) | Cable disconnected from negative (-) battery terminal | 200 Ω or higher | Below 200 Ω: CANL ground short |
| T18-3 (CANH) - I39-16 (BAT) | Cable disconnected from negative (-) battery terminal | 6 kΩ or higher | Below 6 kΩ: CANH +B short |
| T18-2 (CANL) - I39-16 (BAT) | Cable disconnected from negative (-) battery terminal | 6 kΩ or higher | Below 6 kΩ: CANL +B short |
It is only necessary to perform the inspection in the above table for the result (short circuit) that was obtained in the Check Sub Bus 2 inspection.
Find the necessary inspection from the Purpose column that matches the result in the Result column from the Check Sub Bus 2 inspection.
| Result |
|---|
| OK |
| NG |
OK
NG
Reconnect all wire harness connectors (CAN No. 5 junction connector and CAN No. 6 junction connector).
Disconnect the connector that includes terminals CANH and CANL from the ECU to which the bus line shorted to B+ or shorted to GND is connected.
Click herePower Source / Network>NETWORKING>CAN COMMUNICATION SYSTEM>TERMINALS OF ECU
| *a | Component with harness connected
(Network Gateway ECU) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition | Purpose |
|---|---|---|---|
| I160-13 (CA2H) - I160-4 (GND) | Cable disconnected from negative (-) battery terminal | 200 Ω or higher | Below 200 Ω: CANH ground short |
| I160-12 (CA2L) - I160-4 (GND) | Cable disconnected from negative (-) battery terminal | 200 Ω or higher | Below 200 Ω: CANL ground short |
| I160-13 (CA2H) - I160-2 (BATT) | Cable disconnected from negative (-) battery terminal | 6 kΩ or higher | Below 6 kΩ: CANH +B short |
| I160-12 (CA2L) - I160-2 (BATT) | Cable disconnected from negative (-) battery terminal | 6 kΩ or higher | Below 6 kΩ: CANL +B short |
| Result |
|---|
| OK |
| NG |
It is only necessary to perform the inspection in the above table for the result (short circuit) that was obtained in the Check Sub Bus 2 inspection.
If the resistance becomes abnormal when an ECU connector is reconnected, there may be a short in the ECU.
OK
NG